Search icon

D &S PUNCHOUT SOLUTIONS, LLC - Florida Company Profile

Company Details

Entity Name: D &S PUNCHOUT SOLUTIONS, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

D &S PUNCHOUT SOLUTIONS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 29 Jun 2020 (5 years ago)
Document Number: L20000181745
FEI/EIN Number 85-1753836

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1645 Palm Beach Lakes Blvd, WEST PALM BEACH, FL, 33401, US
Mail Address: 1645 Palm Beach Lakes Blvd, WEST PALM BEACH, FL, 33401, US
ZIP code: 33401
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZILNIA HYACINTHE DIEUNANE Auth 725 Dobbins St, WEST PALM BEACH, FL, 33405
Hyacinthe Dieunane Z Agent 725 Dobbins St, WEST PALM BEACH, FL, 33405

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2023-04-12 725 Dobbins St, WEST PALM BEACH, FL 33405 -
CHANGE OF PRINCIPAL ADDRESS 2022-07-27 1645 Palm Beach Lakes Blvd, SUITE 1200, WEST PALM BEACH, FL 33401 -
CHANGE OF MAILING ADDRESS 2022-07-27 1645 Palm Beach Lakes Blvd, SUITE 1200, WEST PALM BEACH, FL 33401 -
REGISTERED AGENT NAME CHANGED 2021-06-09 Hyacinthe, Dieunane Zilnia -

Documents

Name Date
ANNUAL REPORT 2024-01-22
ANNUAL REPORT 2023-04-12
ANNUAL REPORT 2022-03-07
AMENDED ANNUAL REPORT 2021-06-09
ANNUAL REPORT 2021-02-20
Florida Limited Liability 2020-06-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346282833 0418800 2022-08-18 1301 SW 80TH TERRACE, PLANTATION, FL, 33324
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-08-18
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2023-02-16
Abatement Due Date 2023-03-06
Current Penalty 6250.0
Initial Penalty 6250.0
Final Order 2023-03-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Employees on walking/working surfaces with an unprotected side and/or edge which is 6 feet or more above a lower level were not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems: On or about August 18, 2022, at 1301 SW 80th Terrace, Plantation, Florida, employees were exposed to an approximate 12-foot fall hazard while pouring concrete to form a parapet wall without using any means of fall protection.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2023-07-17
Abatement Due Date 2023-08-21
Current Penalty 501.0
Initial Penalty 501.0
Final Order 2023-09-01
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: On or about 07/03/2023, the employer failed to submit certification of corrective action and documentation for citation 1, item 1, issued on 02/16/2023 with an abatement due date of 03/06/2023.
346179062 0418800 2022-05-04 1301 SW 80TH TERRACE, PLANTATION, FL, 33324
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2022-05-04
Emphasis L: FALL

Related Activity

Type Inspection
Activity Nr 1593840
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2022-11-01
Abatement Due Date 2022-11-29
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-11-30
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Employees on walking/working surfaces with an unprotected side and/or edge which is 6 feet or more above a lower level were not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems: On or about May 4, 2022, at 1301 SW 80th Terrace, Plantation, Florida, employees were exposed to an estimated 40-foot fall hazard while engaged in building restoration work from a 4th-floor balcony near the NE corner of the condominium without using any means of fall protection.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2023-02-23
Abatement Due Date 2023-03-30
Current Penalty 501.0
Initial Penalty 501.0
Final Order 2023-03-21
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: a) On or about 01/30/2023, the employer failed to submit documentation and certification of corrective action for citation 1, item 1, issued on 11/01/2022 with an abatement due date of 11/29/2022.

Date of last update: 02 May 2025