Search icon

GENIUS ROOFING SOLUTIONS LLC - Florida Company Profile

Company Details

Entity Name: GENIUS ROOFING SOLUTIONS LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

GENIUS ROOFING SOLUTIONS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Jun 2020 (5 years ago)
Document Number: L20000167195
FEI/EIN Number 85-1561104

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7300 Camino Real, Boca Raton, FL, 33433, US
Mail Address: 7300 Camino Real, Boca Raton, FL, 33433, US
ZIP code: 33433
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZIZZO MARKANTHONY Authorized Member 7300 CAMINO REAL, Boca Raton, FL, 33433
ZIZZO MARKANTHONY Agent 7300 CAMINO REAL, Boca Raton, FL, 33433

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-30 7300 Camino Real, 206, Boca Raton, FL 33433 -
REGISTERED AGENT ADDRESS CHANGED 2024-04-30 7300 CAMINO REAL, Suite 206, Boca Raton, FL 33433 -
CHANGE OF MAILING ADDRESS 2023-11-01 7300 Camino Real, 206, Boca Raton, FL 33433 -

Documents

Name Date
ANNUAL REPORT 2024-04-30
ANNUAL REPORT 2023-04-27
ANNUAL REPORT 2022-09-21
ANNUAL REPORT 2021-09-24
Florida Limited Liability 2020-06-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347441727 0418800 2024-04-26 GREY ST, WEST PALM BEACH, FL, 33407
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-04-26
Emphasis N: FALL, N: RCS-NEP

Related Activity

Type Inspection
Activity Nr 1744185
Safety Yes
Type Referral
Activity Nr 2155975
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee use appropriate eye/face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about April 26, 2024, at Grey Street, West Palm Beach FL 33407, the employer did not ensure eye protection was used for employees who were exposed to eye injuries due to flying projectiles when operating a hand powered saw to cut concrete roofing tiles and using a hand powered blower to blow crystalline silica dust off the roof.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 C
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 2903.4
Initial Penalty 4839.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(c): Employees using hand and power tools and exposed to the hazard of falling, flying, abrasive, or splashing objects, or exposed to harmful dusts, fumes, mists, vapors, or gases were not provided with the particular personal protective equipment. a) On or about April 26, 2024, at Grey Street, West Palm Beach FL 33407, the employer did not ensure hand protection was used for employees who were exposed to hand injuries while operating a hand power saw, hand power blower and handling cut concrete roofing tile.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 5227.2
Initial Penalty 8712.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about April 26, 2024, at Grey Street, West Palm Beach FL 33407, employees were exposed to an approximate 12-foot fall hazard while engaged in roofing work without a conventional fall protection system.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 2613.0
Initial Penalty 4355.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about April 26, 2024, at Grey St West Palm Beach FL 33407, employees were exposed to an approximate 12-foot fall hazard while engaged in roofing work without being trained to recognize the hazards of falling and the procedures to follow in order to minimize these hazards while working on a roof without means of fall protection.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 2613.0
Initial Penalty 4355.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On or about April 26, 2024, at Grey Street, West Palm Beach FL 33407, the employer did not ensure the employees were protected from falls while using an extension ladder to access the roof that was not extended 3-feet above the landing and was not secured at its top to a rigid support, thereby exposing employees to a 12-foot fall hazard.
Citation ID 02001A
Citaton Type Other
Standard Cited 19261153 D02 I
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 489.0
Initial Penalty 815.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: a) On or about April 26, 2024, at Grey St. West Palm Beach FL 33407, the employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica dust at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section for employees while cutting concrete roofing tiles.
Citation ID 02001B
Citaton Type Other
Standard Cited 19261153 G01
Issuance Date 2024-09-06
Abatement Due Date 2024-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-11-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) On or about April 26, 2024, at Grey St West Palm Beach FL 33407, the employer did not develop and implement a written silica exposure control plan for employees exposed to respirable crystalline silica dust while cutting concrete roofing tiles.

Date of last update: 02 Apr 2025