Search icon

CELTIC MANUFACTURING, LLC - Florida Company Profile

Company Details

Entity Name: CELTIC MANUFACTURING, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CELTIC MANUFACTURING, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 22 May 2020 (5 years ago)
Last Event: LC STMNT OF RA/RO CHG
Event Date Filed: 14 Apr 2021 (4 years ago)
Document Number: L20000140345
FEI/EIN Number 85-1368327

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 9755 Delegates Dr, Orlando, FL, 32837, US
Mail Address: 4757 THE GROVE DR, SUITE 220, WINDERMERE, FL, 34786
ZIP code: 32837
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WALL JEREMY H Manager 4757 THE GROVE DR, SUITE 220, WINDERMERE, FL, 34786
Harne Christopher MEsq. Agent 390 N. Orange Avenue, Orlando, FL, 32801

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-01-05 Harne, Christopher M., Esq. -
REGISTERED AGENT ADDRESS CHANGED 2024-01-05 390 N. Orange Avenue, Suite 1600, Orlando, FL 32801 -
CHANGE OF PRINCIPAL ADDRESS 2023-03-07 9755 Delegates Dr, Unit C, Orlando, FL 32837 -
LC STMNT OF RA/RO CHG 2021-04-14 - -

Documents

Name Date
ANNUAL REPORT 2025-01-30
ANNUAL REPORT 2024-01-05
ANNUAL REPORT 2023-03-07
ANNUAL REPORT 2022-01-22
CORLCRACHG 2021-04-14
ANNUAL REPORT 2021-02-06
Florida Limited Liability 2020-05-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347218174 0419730 2024-01-18 9755 DELEGATES DR UNIT C, ORLANDO, FL, 32837
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2024-01-18
Emphasis N: CHROME6
Case Closed 2024-09-08

Related Activity

Type Complaint
Activity Nr 2119835
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2024-07-08
Abatement Due Date 2024-08-01
Current Penalty 3871.8
Initial Penalty 6453.0
Final Order 2024-08-29
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1):The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: a. On or about January 18, 2024, in the paint and sandblasting area: an employee was exposed to respiratory hazards during painting and sandblasting operations, in that, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures for the employee wearing a 3M 6200 Half Face respirator during painting operations and a North 5400 Full Face respirator during sandblasting operations.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2024-07-08
Abatement Due Date 2024-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-29
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace: a. On or about January 18, 2024, in the paint area: an employee was exposed to respiratory hazards during painting operations, in that the employee was required to wear a 3M 6200 Half Face respirator and was not provided with a medical evaluations to determine the employee's ability to wear the respirator. b. On or about January 18, 2024, in the sandblasting area: an employee was exposed to respiratory hazards during sandblasting operations, in that the employee was required to wear a North 5400 Full Face respirator and was not provided with a medical evaluations to determine the employee's ability to wear a respirator.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2024-07-08
Abatement Due Date 2024-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-29
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2):The employer did not ensure that an employee using a tight-fitting respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter: a. On or about January 18, 2024, in the paint area: an employee was exposed to respiratory hazards during painting operations, in that the employee was required to wear a 3M 6200 Half Face respirator and was not provided with a fit test prior to initial use of the respirator. b. On or about January 18, 2024, in the sandblasting area: an employee was exposed to respiratory hazards during sandblasting operations, in that the employee was required to wear a North 5400 Full Face respirator and was not provided with a fit test prior to initial use of the respirator.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19101053 D01
Issuance Date 2024-07-08
Abatement Due Date 2024-08-22
Current Penalty 4840.2
Initial Penalty 8067.0
Final Order 2024-08-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(d)(1):The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section: a. On or about January 18, 2024, in the sandblasting area: an employee was exposed to respiratory hazards during sandblasting operations, in that the employee was required to wear a North 5400 Full Face respirator and the employer did not assess the exposure of each employee who was or may reasonably be exposed to respirable silica at or above the action level. Employees were observed performing daily tasks such as, but not limited to, sandblasting area as remove dirt, paint, grease, and other built-up material from surfaces.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101053 F02 III
Issuance Date 2024-07-08
Abatement Due Date 2024-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(f)(2)(iii):The employer did not make the written exposure control plan readily available for examination and copying, upon request, to each employee covered by this section, their designated representatives, the Assistant Secretary and the Director: a. On or about January 18, 2024, in the sandblasting area: an employee was exposed to respiratory hazards during sandblasting operations, in that the employer did not make the written exposure control plan readily available for examination and copying, upon request, to each employee covered by this section. Employees were observed performing daily tasks such as, but not limited to, sandblasting area as remove dirt, paint, grease, and other built-up material from surfaces .
346837289 0419730 2023-07-18 9400 SOUTHRIDGE PARK COURT, ORLANDO, FL, 32819
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2023-07-18
Case Closed 2023-07-18

Related Activity

Type Complaint
Activity Nr 1933773
Safety Yes

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P3149647 CELTIC MANUFACTURING LLC - WWD8XC62GKK1 9755 DELEGATES DR, ORLANDO, FL, 32837-8333
Capabilities Statement Link -
Phone Number 407-449-2290
Fax Number -
E-mail Address accounting@celticmanufacturing.com
WWW Page -
E-Commerce Website http://www.celticengineering.com/
Contact Person JACOB JORDAN
County Code (3 digit) 095
Congressional District 09
Metropolitan Statistical Area 5960
CAGE Code 9LE12
Year Established 2020
Accepts Government Credit Card Yes
Legal Structure LLC
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office NORTH FLORIDA DISTRICT OFFICE (SBA office code 0491)
Capabilities Narrative metal manufacturing, welding, engineering, fabrication, supplier, certified welding inspector, quality control, qaqc, manufacturing, armament, ffl, itar certified, composites, carbon fiber, machining, laser, design, fatigue analysis, strength calculations, fea analysis, iso compliant,
Special Equipment/Materials (none given)
Business Type Percentages Construction (5 %) Manufacturing (90 %) Research and Development (5 %)
Keywords metal manufacturing, welding, engineering, fabrication, supplier, certified welding inspector, quality control, qaqc, manufacturing, armament, ffl, itar certified, composites, carbon fiber, machining, laser, design, fatigue analysis, strength calculations, fea analysis, iso compliant
Quality Assurance Standards ISO-9000 SeriesANSI/ASQC Z1.4MIL-STD-45662AMIL-Q-9858ISO 10012-1
Electronic Data Interchange capable -

Current Principals

Name Jeremy Wall
Role President
Name Jacob Jordan
Role Vice President

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level $0
Description Construction Bonding Level (aggregate)
Level $0
Description Service Bonding Level (per contract)
Level $0
Description Service Bonding Level (aggregate)
Level $0

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 333248
NAICS Code's Description All Other Industrial Machinery Manufacturing
Buy Green Yes
Code 327999
NAICS Code's Description All Other Miscellaneous Nonmetallic Mineral Product Manufacturing
Buy Green Yes
Code 332312
NAICS Code's Description Fabricated Structural Metal Manufacturing
Buy Green Yes
Code 332313
NAICS Code's Description Plate Work Manufacturing
Buy Green Yes
Code 332999
NAICS Code's Description All Other Miscellaneous Fabricated Metal Product Manufacturing
Buy Green Yes
Code 335132
NAICS Code's Description Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Yes
Export Business Activities Manufacturer, Consultant, Other
Exporting to Japan; United Kingdom
Desired Export Business Relationships Direct export sales, Overseas retailers, Joint venture/coventure, Alliances, Investment
Description of Export Objective(s) Provide custom manufactured parts to clients worldwide

Performance History (References)

Name Jacob Jordan
Contract NDA
Start 2024-03-01
Value 75,000,000,000.00
Contact Jacob Jordan
Phone 407-449-2290

Date of last update: 02 Apr 2025

Sources: Florida Department of State