Search icon

KENZIE GRACE CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: KENZIE GRACE CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

KENZIE GRACE CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 15 Apr 2020 (5 years ago)
Document Number: L20000103278
FEI/EIN Number 85-0720209

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 15620-B MLK Blvd, Dover, FL, 33527, US
Mail Address: PO Box 837, Dover, FL, 33527, US
ZIP code: 33527
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TOMLINSON JEFF Manager 15620-B MLK Blvd, Dover, FL, 33527
MCBREEN DANIEL J Agent 115 S. FIELDING AVENUE, TAMPA, FL, 33606

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2022-02-28 MCBREEN, DANIEL J -
CHANGE OF PRINCIPAL ADDRESS 2021-04-19 15620-B MLK Blvd, Dover, FL 33527 -
CHANGE OF MAILING ADDRESS 2021-04-19 15620-B MLK Blvd, Dover, FL 33527 -
REGISTERED AGENT ADDRESS CHANGED 2021-04-19 115 S. FIELDING AVENUE, SUITE 3, TAMPA, FL 33606 -

Documents

Name Date
ANNUAL REPORT 2024-02-14
ANNUAL REPORT 2023-01-23
ANNUAL REPORT 2022-02-28
ANNUAL REPORT 2021-04-19
Florida Limited Liability 2020-04-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347344913 0420600 2024-03-13 6192 HIDDEN BRANCH, APOLLO BEACH, FL, 33572
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-03-13
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-03-28
Abatement Due Date 2024-04-09
Current Penalty 6452.0
Initial Penalty 6452.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On a scaffold at a residence, located at 6192 Hidden Branch, Apollo Beach, Florida 33572: on or about 3/13/24, the employer exposed employees to fall hazards, in that the scaffold platform was not fully planked while employees were performing siding work.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2024-03-28
Abatement Due Date 2024-04-09
Current Penalty 0.0
Initial Penalty 6452.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. On a scaffold at a residence, located at 6192 Hidden Branch, Apollo Beach, Florida 33572: on or about 3/13/24, the employer exposed employees to fall hazards, in that fall protection was not utilized while employees were performing siding work.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2024-03-28
Abatement Due Date 2024-04-09
Current Penalty 6452.0
Initial Penalty 6452.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. On a scaffold at a residence, located at 6192 Hidden Branch, Apollo Beach, Florida 33572: on or about 3/13/24, the employer exposed employees to fall hazards, in that the scaffold was not restrained from tipping while employees were performing siding work.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2024-03-28
Abatement Due Date 2024-04-09
Current Penalty 0.0
Initial Penalty 6452.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: On a scaffold at a residence, located at 6192 Hidden Branch, Apollo Beach, Florida 33572: on or about 3/13/24, the employer exposed employees to fall hazards, in that the scaffold poles did not have mud sills while employees were performing siding work.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-03-28
Abatement Due Date 2024-04-09
Current Penalty 4610.0
Initial Penalty 4610.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On a scaffold at a residence, located at 6192 Hidden Branch, Apollo Beach, Florida 33572: on or about 3/13/24, the employer exposed employees to fall hazards, in that a safe access point was not installed while employees were performing siding work.