Search icon

JACOB STUCCO LLC - Florida Company Profile

Company Details

Entity Name: JACOB STUCCO LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

JACOB STUCCO LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 30 Sep 2019 (6 years ago)
Date of dissolution: 22 Sep 2023 (2 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2023 (2 years ago)
Document Number: L19000246331
FEI/EIN Number 35-2674938

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 618 SAN JUAN BLVD, ORLANDO, FL, 32807
Mail Address: 618 SAN JUAN BLVD, ORLANDO, FL, 32807
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZUMBA SUMBA JAIME ABMR 618 SAN JUAN BLVD, ORLANDO, FL, 32807
ZUMBA JAIME O Agent 618 SAN JUAN BLVD, ORLANDO, FL, 32807

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G21000117307 STUCCO ORLANDO ACTIVE 2021-09-13 2026-12-31 - 618 SAN JUAN BLVD, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
REINSTATEMENT 2022-09-27 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -
REGISTERED AGENT NAME CHANGED 2021-01-07 ZUMBA, JAIME O -
LC AMENDMENT 2020-07-21 - -

Documents

Name Date
REINSTATEMENT 2022-09-27
ANNUAL REPORT 2021-01-07
ANNUAL REPORT 2020-09-25
LC Amendment 2020-07-21
Florida Limited Liability 2019-09-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346526411 0420600 2023-02-23 1299 SOUTH GOODMAN ROAD, CHAMPIONS GATE, FL, 33896
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-02-24
Emphasis L: FALL
Case Closed 2024-05-21

Related Activity

Type Referral
Activity Nr 2002364
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2023-05-16
Abatement Due Date 2023-05-26
Current Penalty 2679.0
Initial Penalty 2679.0
Final Order 2023-06-22
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL: employees were exposed to fall hazards of approximately 6 feet 6 inches in that the spacing in between the individual walk planks and the spacing between the platform and the uprights was approximately 2.5 inches.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2023-05-16
Abatement Due Date 2023-05-26
Current Penalty 2679.0
Initial Penalty 2679.0
Final Order 2023-06-22
Nr Instances 3
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm) (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL. employees were exposed to fall hazards in that individual walk planks extended approximately 4.5 inches over the center line of its support and were not cleated or otherwise restrained.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G04 VII
Issuance Date 2023-05-16
Abatement Due Date 2023-06-12
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-06-22
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(vii):Each toprail or equivalent member of a guardrail system was not capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) or guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL. employees were exposed to fall hazards of approximately 13 feet 3 inches in that the scaffold guardrail system was erected in such a way that it was not capable of supporting at least 200 pounds.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260454 A
Issuance Date 2023-05-16
Abatement Due Date 2023-07-05
Current Penalty 9375.0
Initial Penalty 9375.0
Final Order 2023-06-22
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL: employees were exposed to fall hazards of approximately 13 feet 3 inches while working from a scaffold, in that they were not trained in the hazards associated with working from a scaffold system. Jacob Stucco LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.454(a) which was contained in OSHA inspection number 1496184, citation number 1, item number 2 and was affirmed as a final order on 04/12/2021, with respect to a workplace located at 600 E. Bay Street, Building A3, Lakeland, Florida 33801.
345613939 0419700 2021-11-02 7507 PARK VILLAGE DRIVE, JACKSONVILLE, FL, 32256
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-11-02
Emphasis N: CTARGET, L: FALL, P: FALL
Case Closed 2022-06-08

Related Activity

Type Inspection
Activity Nr 1561401
Safety Yes
Type Inspection
Activity Nr 1561378
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G02
Issuance Date 2022-03-02
Current Penalty 2871.6
Initial Penalty 4786.0
Final Order 2022-03-24
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(2):The employer did not provide fall protection for employees erecting or dismantling supported scaffolds: a. In the balcony and scaffold decking at the front of the building #400, located at 7507 Park Village Drive, Jacksonville FL: On or about November 2, 2021, the employer exposed two employees to a 34 foot and higher fall hazards, in that fall protection was not utilized by employees unloading scaffold parts from a Telescopic Handler.
344961842 0420600 2020-10-06 600 E. BAY STREET BUILDING A3, LAKELAND, FL, 33801
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-10-06
Emphasis P: CTARGET, N: CTARGET
Case Closed 2021-07-23

Related Activity

Type Inspection
Activity Nr 1496167
Safety Yes
Type Inspection
Activity Nr 1496153
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2021-03-15
Abatement Due Date 2021-04-08
Current Penalty 1755.6
Initial Penalty 2926.0
Final Order 2021-04-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) On or about October 6, 2020, at the west side of the residential apartment building, the corner end side of the second level of the supported scaffold used by employees to clean stucco on the wall had no guardrail system installed, exposing the employees to a 13.3 foot fall hazard.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G04 XV
Issuance Date 2021-03-15
Abatement Due Date 2021-04-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-04-12
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(xv): Crossbracing used in place of a midrail was unacceptable because the crossing point of two braces is between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a toprail when the crossing point of two braces is not between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The endpoints at each upright were more than 48 inches (1.3 m) apart. a) On or about October 6, 2020, at the west side of the residential apartment building, the third level corner end side of the supported scaffold used by employees to clean stucco off the wall was missing guard rail components, exposing the employees to a 20 foot fall hazard. b) On or about October 6, 2020, at the west side of the residential apartment building, the middle column second level of the supported scaffold used by employees to clean stucco off the wall was missing guard rail components, exposing the employees to a 13.3 foot fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2021-03-15
Abatement Due Date 2021-04-08
Current Penalty 1755.6
Initial Penalty 2926.0
Final Order 2021-04-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On or about October 6, 2020, at the west side of the residential apartment building, employees working on a supported scaffold while cleaning stucco on the exterior wall had not been trained on the hazards of the scaffold system.