Entity Name: | AFFORDABLE CUSTOM BUILDERS LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
AFFORDABLE CUSTOM BUILDERS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Jul 2019 (6 years ago) |
Date of dissolution: | 23 Sep 2022 (2 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2022 (2 years ago) |
Document Number: | L19000178813 |
FEI/EIN Number |
NOT APPLICABLE
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 12721 METRO PKY, FORT MYERS, FL, 33966, US |
Mail Address: | 12721 METRO PKY, FORT MYERS, FL, 33966, US |
ZIP code: | 33966 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ELRASHEDY WALID | Manager | 12721 METRO PKY, FORT MYERS, FL, 33966 |
ELRASHEDY WALID | Agent | 12721 METRO PKY, FORT MYERS, FL, 33966 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2022-09-23 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2021-05-01 |
ANNUAL REPORT | 2020-06-27 |
Florida Limited Liability | 2019-07-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345144570 | 0420600 | 2021-02-11 | 4213 BLOOMFIELD STREET, FORT MYERS, FL, 33916 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1732681 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2021-05-05 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-06-02 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) While at the jobsite, employees were performing roof sheathing on a 5/12 slope and framing the roofing area of a residence without fall protection, exposing the employees to a fall hazard approximately 10' feet on or about 11 February 2021. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2021-05-05 |
Current Penalty | 2341.0 |
Initial Penalty | 2341.0 |
Final Order | 2021-06-02 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On the south (front of home) east side, a 12' extension ladder was being utilized that was not long enough to extend 3 feet above the roof edge. The ladder extended approximately 1' over the edge, exposing the employees to a fall hazard on or about 11 February 2021. |
Date of last update: 01 Mar 2025