Search icon

AFFORDABLE CUSTOM BUILDERS LLC - Florida Company Profile

Company Details

Entity Name: AFFORDABLE CUSTOM BUILDERS LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

AFFORDABLE CUSTOM BUILDERS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 11 Jul 2019 (6 years ago)
Date of dissolution: 23 Sep 2022 (2 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2022 (2 years ago)
Document Number: L19000178813
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 12721 METRO PKY, FORT MYERS, FL, 33966, US
Mail Address: 12721 METRO PKY, FORT MYERS, FL, 33966, US
ZIP code: 33966
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ELRASHEDY WALID Manager 12721 METRO PKY, FORT MYERS, FL, 33966
ELRASHEDY WALID Agent 12721 METRO PKY, FORT MYERS, FL, 33966

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -

Documents

Name Date
ANNUAL REPORT 2021-05-01
ANNUAL REPORT 2020-06-27
Florida Limited Liability 2019-07-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345144570 0420600 2021-02-11 4213 BLOOMFIELD STREET, FORT MYERS, FL, 33916
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2021-02-11
Emphasis L: FALL
Case Closed 2022-11-09

Related Activity

Type Complaint
Activity Nr 1732681
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2021-05-05
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) While at the jobsite, employees were performing roof sheathing on a 5/12 slope and framing the roofing area of a residence without fall protection, exposing the employees to a fall hazard approximately 10' feet on or about 11 February 2021.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2021-05-05
Current Penalty 2341.0
Initial Penalty 2341.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On the south (front of home) east side, a 12' extension ladder was being utilized that was not long enough to extend 3 feet above the roof edge. The ladder extended approximately 1' over the edge, exposing the employees to a fall hazard on or about 11 February 2021.