Entity Name: | TACTICAL ROOFING SOLUTIONS LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
TACTICAL ROOFING SOLUTIONS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 24 May 2019 (6 years ago) |
Document Number: | L19000139516 |
FEI/EIN Number |
84-1975843
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 441 Del Prado Blvd N, Unit 7, CAPE CORAL, FL, 33909, US |
Mail Address: | 441 Del Prado Blvd N, Unit 7, CAPE CORAL, FL, 33909, US |
ZIP code: | 33909 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
PALMIERI MICHAEL | President | 8501 Dosonte Ln, North Fort Myers, FL, 33917 |
PALMIERI KIMBERLY A | Vice President | 8501 Dosonte Ln, North Fort Myers, FL, 33917 |
PALMIERI MICHAEL | Agent | 8501 Dosonte Ln, North Fort Myers, FL, 33917 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT ADDRESS CHANGED | 2023-02-17 | 8501 Dosonte Ln, North Fort Myers, FL 33917 | - |
REGISTERED AGENT NAME CHANGED | 2021-02-17 | PALMIERI, MICHAEL | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-18 |
ANNUAL REPORT | 2023-02-17 |
ANNUAL REPORT | 2022-03-07 |
ANNUAL REPORT | 2021-02-17 |
ANNUAL REPORT | 2020-09-04 |
Florida Limited Liability | 2019-05-24 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346964265 | 0420600 | 2023-09-05 | 2110 HOOPLE ST, FORT MYERS, FL, 33901 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2075346 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2023-11-14 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-12-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite located at 2110 Hoople St, Fort Myers, FL 33901; On or about 09/05/2023, the employer exposed employees to fall hazards, in that fall protection was not utilized by employees while performing roofing activities such as but not limited to installation of sheathing on a 6:12 pitch residential home roof approximately 20 feet in height. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-11-14 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-12-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) At the jobsite located at 2110 Hoople Ave , Fort Myers, FL 33901; On or about 09/05/2023, the employer exposed employees to injuries, in that the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2023-11-14 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-12-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6):Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement. a) At the jobsite located at 2110 Hoople Ave , Fort Myers, FL 33901; On or about 09/05/2023, the employer exposed employees to injuries, in that the ladder was placed on the top step of a staircase that was not secure or stable to prevent displacement |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261053 B08 |
Issuance Date | 2023-11-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-12-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(8):Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder. a) At the jobsite located at 2110 Hoople Ave , Fort Myers, FL 33901; On or about 09/05/2023, the employer exposed employees to injuries, in that the Ladder was placed in the doorway was not secure to prevent displacement, a barricade was not used on the door to keep activities or traffic away from the ladder. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2023-06-22 |
Emphasis | L: FALL, N: FALL |
Related Activity
Type | Complaint |
Activity Nr | 2044154 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B02 |
Issuance Date | 2023-10-10 |
Abatement Due Date | 2023-11-03 |
Current Penalty | 3375.0 |
Initial Penalty | 5625.0 |
Final Order | 2023-11-02 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(2):The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). a.) At the jobsite, located at 105 Tropicana Pkwy E, Cape Coral, FL, On or about August 1, 2023; the employer exposed employees to fall hazards, in that employees were using a portable ladder for access to the roof work area approximately 8 feet in height which was set up for use incorrectly. No competent person performed an inspection to ensure the ladder was set up correctly. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B05 I |
Issuance Date | 2023-10-10 |
Abatement Due Date | 2023-11-03 |
Current Penalty | 3375.0 |
Initial Penalty | 5625.0 |
Final Order | 2023-11-02 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder. a.) At the jobsite, located at 105 Tropicana Pkwy E, Cape Coral, FL, On or about August 1, 2023; the employer exposed employees to fall hazards, in that, employees were installing roofing material on a residential roof approximate 8 feet in height using a portable aluminum ladder for access where the ladder base was extended approximately 58 degrees creating a fall hazard. |