Search icon

D CATALAN CONSTRUCTION LLC - Florida Company Profile

Company Details

Entity Name: D CATALAN CONSTRUCTION LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

D CATALAN CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 14 May 2019 (6 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 05 Jan 2024 (a year ago)
Document Number: L19000130857
FEI/EIN Number 84-1867842

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5844 SE COLLINS AVENUE, STUART, FL, 34997, US
Mail Address: 5844 SE COLLINS AVENUE, STUART, FL, 34997, US
ZIP code: 34997
County: Martin
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CATALAN DERICK I Manager 5844 SE COLLINS AVENUE, STUART, FL, 34997
CATALAN DERICK I Agent 5844 SE COLLINS AVENUE, STUART, FL, 34997

Events

Event Type Filed Date Value Description
REINSTATEMENT 2024-01-05 - -
REGISTERED AGENT NAME CHANGED 2024-01-05 CATALAN, DERICK I -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J21000656425 TERMINATED 1000000910746 MARTIN 2021-12-13 2031-12-22 $ 1,019.31 STATE OF FLORIDA, DEPARTMENT OF REVENUE, FORT PIERCE SERVICE CENTER, 337 N US HIGHWAY 1 STE 207-B, FORT PIERCE FL349504255
J21000098792 TERMINATED 1000000878880 MARTIN 2021-03-01 2031-03-03 $ 868.64 STATE OF FLORIDA, DEPARTMENT OF REVENUE, FORT PIERCE SERVICE CENTER, 337 N US HIGHWAY 1 STE 207-B, FORT PIERCE FL349504255

Documents

Name Date
REINSTATEMENT 2024-01-05
ANNUAL REPORT 2021-04-28
ANNUAL REPORT 2020-06-19
Florida Limited Liability 2019-05-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344735600 0418800 2020-04-27 2783 NE 31ST COURT, LIGHTHOUSE POINT, FL, 33064
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2020-04-27
Emphasis L: OHPWRLNE
Case Closed 2023-04-13

Related Activity

Type Inspection
Activity Nr 1473545
Safety Yes
Type Inspection
Activity Nr 1473561
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260416 A01
Issuance Date 2020-09-08
Abatement Due Date 2020-09-18
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-10-13
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was exposed to an electrocution hazard while attaching pallets of lintels on to a crane joist which was located within approximately 5 feet or less of overhead power lines energized with 7,600 volts.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260416 A03
Issuance Date 2020-09-08
Abatement Due Date 2020-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit: On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working within approximately 5 feet or less of overhead power lines energized with 7,600 volts, without the employer conducting an assessment of the powerlines before allowing the employee to commence work, exposing the employee to a electrocution hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-09-08
Abatement Due Date 2020-09-18
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about September 27, 2020, on the top of the second floor of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working without the use of fall protection, exposing the employee to a fall hazard of approximately 10 feet.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2020-09-08
Abatement Due Date 2020-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about September 27, 2020, on the top of the second floor of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working without the use of fall protection nor fall protection training exposing the employee to a fall hazard of approximately 10 feet.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2020-09-08
Abatement Due Date 2020-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-10-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): On or about September 27, 2020, on the right side of the front of the new home under construction, located at 2783 NE 31st. Ct. Lighthouse Point, FL, an employee was working on the second floor of the home without the employer conducting a jobsite inspection before allowing the employee to commence work, exposing the employee to a fall hazard of approximately 10 feet.
Citation ID 02001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2021-09-30
Abatement Due Date 2021-11-04
Current Penalty 329.0
Initial Penalty 329.0
Final Order 2021-10-27
Nr Instances 4
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 1b, issued on 09/08/2020 with an abatement due date of 09/18/2020. b) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2a, issued on 09/08/2020 with an abatement due date of 09/18/2020. c) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2b, issued on 09/08/2020 with an abatement due date of 09/18/2020. c) On or about 08/10/2021, the employer failed to submit certification of corrective action for citation 1, item 2c, issued on 09/08/2020 with an abatement due date of 09/18/2020.
Citation ID 02001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2021-09-30
Abatement Due Date 2021-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-10-27
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: a) On or about 08/10/2021, the employer failed to submit documentation and certification of corrective action for citation 1, item 1a, issued on 09/08/2020 with an abatement due date of 09/18/2020.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1823927702 2020-05-01 0455 PPP 5844 SE COLLINS AVE, STUART, FL, 34997
Loan Status Date 2021-07-22
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 17250
Loan Approval Amount (current) 17250
Undisbursed Amount 0
Franchise Name -
Lender Location ID 48270
Servicing Lender Name JPMorgan Chase Bank, National Association
Servicing Lender Address 1111 Polaris Pkwy, COLUMBUS, OH, 43240-2031
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description New Business or 2 years or less
Project Address STUART, MARTIN, FL, 34997-0019
Project Congressional District FL-21
Number of Employees 8
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 194093
Originating Lender Name JPMorgan Chase Bank, National Association
Originating Lender Address CHICAGO, IL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 17442.53
Forgiveness Paid Date 2021-06-16

Date of last update: 02 Mar 2025

Sources: Florida Department of State