Search icon

ALVAROB SERVICES LLC - Florida Company Profile

Company Details

Entity Name: ALVAROB SERVICES LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ALVAROB SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 28 Mar 2019 (6 years ago)
Document Number: L19000086795
FEI/EIN Number 320599012

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 550 SUNDOWN CT, APOPKA, FL, 32712, US
Mail Address: 550 SUNDOWN CT, APOPKA, FL, 32712, US
ZIP code: 32712
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ALVARADO RAMIREZ YEISI M Manager 550 SUNDOWN CT, APOPKA, FL, 32712
ALVARADO RAMIREZ YEISI M Agent 550 SUNDOWN CT, APOPKA, FL, 32712

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2021-04-29 ALVARADO RAMIREZ, YEISI M -

Documents

Name Date
ANNUAL REPORT 2024-01-17
ANNUAL REPORT 2023-01-27
ANNUAL REPORT 2022-04-30
ANNUAL REPORT 2021-04-29
ANNUAL REPORT 2020-03-03
Florida Limited Liability 2019-03-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347040032 0420600 2023-10-11 13450 GREENGATE BLVD., FORT MYERS, FL, 33919
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-10-11
Emphasis N: FALL
Case Closed 2024-04-02

Related Activity

Type Inspection
Activity Nr 1703996
Safety Yes
Type Complaint
Activity Nr 2088558
Safety Yes
Type Inspection
Activity Nr 1706968
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-11-20
Current Penalty 6250.0
Initial Penalty 6250.0
Final Order 2023-12-26
Nr Instances 1
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 10/11/2023, at the jobsite located at 13450 Greengate Blvd, Fort Myers, Florida 33919, employees were exposed to fall hazards of approximately 17 feet 9 inches, in that, fall protection was not used while engaged in roofing activities while on a second story roof.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-11-20
Current Penalty 6250.0
Initial Penalty 6250.0
Final Order 2023-12-26
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 10/11/2023, at the jobsite located at 13450 Greengate Blvd, Fort Myers, Florida 33919, employees were exposed to fall hazards of approximately 17 feet 9 inches, in that, the extension ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2023-11-20
Current Penalty 6250.0
Initial Penalty 6250.0
Final Order 2023-12-26
Nr Instances 1
Nr Exposed 14
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i):Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support) a) On or about 10/11/2023, at the jobsite located at 13450 Greengate Blvd, Fort Myers, Florida 33919, employees were exposed to fall hazards of approximately 17 feet 9 inches, in that, the angle of the extension ladder in use to gain access to the roof was too shallow, 64.9 degrees.