Entity Name: | BABCOCK CONSTRUCTION, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
BABCOCK CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 25 Feb 2019 (6 years ago) |
Date of dissolution: | 22 Aug 2024 (8 months ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 22 Aug 2024 (8 months ago) |
Document Number: | L19000053993 |
FEI/EIN Number |
83-3811724
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 6488 Bahaia rd, Fleming island, FL, 32003, US |
Mail Address: | 6488 Bahaia rd, Fleming island, FL, 32003, US |
ZIP code: | 32003 |
County: | Clay |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Babcock Johnathon D | Manager | 6488 Bahaia rd, Fleming island, FL, 32003 |
Babcock Ashley L | Manager | 6488 Bahaia rd, Fleming island, FL, 32003 |
BABCOCK JOHNATHON D | Agent | 6488 Bahaia rd, Fleming island, FL, 32003 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2024-08-22 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2022-08-03 | 6488 Bahaia rd, Fleming island, FL 32003 | - |
CHANGE OF MAILING ADDRESS | 2022-08-03 | 6488 Bahaia rd, Fleming island, FL 32003 | - |
REGISTERED AGENT ADDRESS CHANGED | 2022-08-03 | 6488 Bahaia rd, Fleming island, FL 32003 | - |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2024-08-22 |
ANNUAL REPORT | 2023-09-21 |
ANNUAL REPORT | 2022-08-03 |
ANNUAL REPORT | 2021-04-30 |
ANNUAL REPORT | 2020-06-30 |
Florida Limited Liability | 2019-02-25 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344550629 | 0419700 | 2020-01-10 | 702 SEVILLE PARKWAY LOT 151 ANDALUSIA, SAINT AUGUSTINE, FL, 32086 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2020-03-13 |
Current Penalty | 4626.0 |
Initial Penalty | 4626.0 |
Final Order | 2020-04-28 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about January 10, 2020, on the 6:12 pitch roof 4 roofing employees installing roofing paper to dry-in the roof, were exposed to a 9 feet fall hazard in that they were not protected by a fall protection system. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2020-03-13 |
Current Penalty | 3084.0 |
Initial Penalty | 3084.0 |
Final Order | 2020-04-28 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about January 10, 2020, at the right front corner of the house, the roof access ladder did not extend at least 3 feet above the edge of the roof, exposing 4 employees to a 9 feet fall hazard from the eave. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 A01 |
Issuance Date | 2020-03-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-04-28 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): A training program was not provided to each employee who might be exposed to fall hazards, to enable that employee to recognize the hazards of falling, and be trained in the procedures to be followed to minimize these hazards: a. On or about January 10, 2020, on the 6:12 pitch roof, the employer had not trained employees exposed to 9 feet fall hazards how to properly install anchor devices as part of their fall protection systems. |