Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-04-05
|
Emphasis |
L: FALL
|
Related Activity
Type |
Complaint |
Activity Nr |
1881435 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1587681 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2022-09-26 |
Abatement Due Date |
2022-10-06 |
Current Penalty |
4351.0 |
Initial Penalty |
4351.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At 11801 1st Street East Treasure Island (FL): On or about April 05, 2022, employees without fall protection were exposed to falls while working approximately 17 feet from the ground while installing decking. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260701 B |
Issuance Date |
2022-09-26 |
Abatement Due Date |
2022-10-06 |
Current Penalty |
2486.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a) At 11801 1st Street East Treasure Island (FL): On or about April 5, 2022, employees were exposed to impalement while decking near uncapped rebar. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2022-09-26 |
Current Penalty |
3729.0 |
Initial Penalty |
3729.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) At 11801 1st Street E Treasure Island (FL): On or about April 5, 2022, employees were using a job made wooden ladder with side rails that did not extend a minimum of three feet above the second floor landing. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 A11 |
Issuance Date |
2022-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(a)(11):Ladder components were not surfaced to prevent injury to employees from punctures or lacerations, and/or to prevent snagging of clothing: (a) At 11801 1st Street East Treasure Island (FL): On or about April 5, 2022 , employees were exposed to lacerations and pucture wounds while using a job made wooden ladder constructed with duplex nails and protruding screws along its side rails. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260404 F06 |
Issuance Date |
2022-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6):The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) At 11801 1st Street East Treasure Island (FL): On or about April 5, 2022, employees were exposed to burns while using an extension cord used for hand tool battery charging station that was missing its ground pin. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2022-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) At 11801 1st Street East Treasure Island (FL): On or about April 05, 2022, employees were exposed to electrical hazards while using an extension cord with a damaged strain relief to power a hand tool. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19261060 A |
Issuance Date |
2022-09-26 |
Abatement Due Date |
2022-10-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-10-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a):The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) At 11801 1st Street East Treasure Island (FL): On or about April 5, 2022, employees were exposed to injuries while using improperly constructed wooden job made ladder to access the second story landing. |
|
|