Entity Name: | READY ROOFING, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
READY ROOFING, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 24 Jan 2019 (6 years ago) |
Document Number: | L19000025157 |
FEI/EIN Number |
833573783
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5105 Philips Hwy, Jacksonville, FL, 32207, US |
Mail Address: | 5105 Philips Hwy, Jacksonville, FL, 32207, US |
ZIP code: | 32207 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Jessup Jim | Authorized Member | 5105 Philips Hwy, Jacksonville, FL, 32207 |
JESSUP JIM | Agent | 5105 Philips Hwy, Jacksonville, FL, 32207 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2023-08-01 | 5105 Philips Hwy, 205, Jacksonville, FL 32207 | - |
CHANGE OF MAILING ADDRESS | 2023-08-01 | 5105 Philips Hwy, 205, Jacksonville, FL 32207 | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-08-01 | 5105 Philips Hwy, 205, Jacksonville, FL 32207 | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J20000413548 | ACTIVE | CC20-1596 | ST. JOHN'S COUNTY COURT CLERK | 2020-10-30 | 2025-12-21 | $27,705.02 | SRS DISTRIBUTION INC., 5900 S LAKE FOREST DRIVE #400, MCKINNEY, TX, 75070 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-09 |
ANNUAL REPORT | 2023-08-01 |
ANNUAL REPORT | 2022-04-07 |
ANNUAL REPORT | 2021-04-10 |
ANNUAL REPORT | 2020-06-16 |
Florida Limited Liability | 2019-01-24 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347544678 | 0419700 | 2024-06-12 | 2351 3RD AVE, JACKSONVILLE, FL, 32208 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-07-10 |
Current Penalty | 2903.5 |
Initial Penalty | 5807.0 |
Final Order | 2024-08-05 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On a 5/12 pitched residential roof located at 2351 3rd Avenue in Jacksonville Florida: On or about June 12, 2022, the employer exposed employees to fall hazards ranging from 9 to 14-foot, in that fall protection was not utilized by employees, while performing roofing work . |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-07-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-08-05 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On a 5/12 pitched residential roof located at 2351 3rd Avenue in Jacksonville Florida: On June 12, 2024, the employer exposed employees to fall hazards ranging from 6 to 11-feet, in that the portable ladder used to access the roof was not extended at least 3-foot above the upper landing surface. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State