Search icon

RAMIREZ STUCCO, LLC - Florida Company Profile

Company Details

Entity Name: RAMIREZ STUCCO, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

RAMIREZ STUCCO, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 29 Jan 2019 (6 years ago)
Document Number: L19000024698
FEI/EIN Number 833354973

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2205 COCHRAN ST, LAKELAND, FL, 33815, US
Mail Address: 2205 COCHRAN ST, LAKELAND, FL, 33815, US
ZIP code: 33815
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RAMIREZ JAIRO A Manager 2205 COCHRAN ST, LAKELAND, FL, 33815
RAMIREZ JAIRO Agent 2205 COCHRAN ST, LAKELAND, FL, 33815

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-04-04 RAMIREZ, JAIRO -
REGISTERED AGENT ADDRESS CHANGED 2024-04-04 2205 COCHRAN ST, LAKELAND, FL 33815 -

Documents

Name Date
ANNUAL REPORT 2024-04-04
ANNUAL REPORT 2023-04-30
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-02-03
ANNUAL REPORT 2020-04-27
Florida Limited Liability 2019-01-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343948972 0420600 2019-03-26 7793 ROMA DUNE DRIVE, WESLEY CHAPEL, FL, 33545
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-03-26
Emphasis L: FALL, P: FALL
Case Closed 2023-11-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-09-25
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about March 26, 2019, an employee not wearing eye protection while using a pneumatic stapler gun to install metal mesh for stucco application was exposed to struck-by hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-09-25
Abatement Due Date 2019-10-07
Current Penalty 1705.2
Initial Penalty 2842.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about March 26, 2019, at the front and left sides of a two story residential building, employees were exposed to a fall hazard of 10 feet, 7 inches while installing metal mesh on the walls without using a fall protection system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2019-09-25
Abatement Due Date 2019-10-07
Current Penalty 1705.2
Initial Penalty 2842.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) On or about March 26, 2019, at the front of the residential building above the single car garage, an employee on the roof utilized an "A" Frame Werner 5 step ladder folded against the wall while installing metal wire mesh for stucco, exposing them to a 9 foot 4 inch fall to the ground.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2019-09-25
Abatement Due Date 2019-10-07
Current Penalty 1705.2
Initial Penalty 2842.0
Final Order 2019-10-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the length of the ladder: (a) On or about March 26, 2019, employees were exposed to a 9 foot 8 inch fall while using a 24 foot Louisville metal extension ladder to access a 5:12 pitch roof. The ladder was set up 18 feet high and 6 feet away from the top support of the ladder. b) On or about March 26, 2019, employees were exposed to a 9 foot 8 inch fall while using a 20 foot Werner metal extension ladder to access a 5:12 pitch roof. The ladder was set up 13 feet high and 5 feet 9 inches away from the top support of the ladder.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B15
Issuance Date 2019-09-25
Abatement Due Date 2019-10-07
Current Penalty 1363.8
Initial Penalty 2273.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) On or about March 26, 2019, at the front of a residential building car garage area, employees were exposed to falls while utilizing a Werner metal extension ladder (24 ft.) with missing foot assemblies for access and egress to a 5:12 pitch roof.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2019-09-25
Abatement Due Date 2019-10-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about March 26, 2019, for employees installing metal mesh to a two story residential building from a 5:12 pitch roof from the leading edge without using a fall protection system. Employees exposed to a fall hazard of approximately 9 feet 4 inches.
Citation ID 02002
Citaton Type Other
Standard Cited 19261060 A01 III
Issuance Date 2019-09-25
Abatement Due Date 2019-10-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-09
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: (a) On or about March 26, 2019, for employees using 6-foot, 20-foot and 24-foot portable extension ladders to access the 5:12 pitch roof to install metal mesh onto the walls for stucco application.