Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

YJ CORDERO, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 22 Jan 2019 (6 years ago)
Document Number: L19000022629
FEI/EIN Number 301163643

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5656 KALMIA, ORLANDO, FL, 32807, US
Mail Address: 5656 KALMIA, ORLANDO, FL, 32807, US
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CORDERO SALAZAR YEISON J Manager 5656 KALMIA DR, ORLANDO, FL, 32807
CORDERO SALAZAR YEISON J Agent 5656 KALMIA DR, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2021-03-26 CORDERO SALAZAR, YEISON J -

Documents

Name Date
ANNUAL REPORT 2024-02-20
ANNUAL REPORT 2023-02-01
ANNUAL REPORT 2022-05-05
ANNUAL REPORT 2021-03-26
ANNUAL REPORT 2020-04-22
Florida Limited Liability 2019-01-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346816721 0420600 2023-07-07 1200 102ND AVE N, SAINT PETERSBURG, FL, 33716
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-07-07
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1681667
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2023-09-14
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-10-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a.)At the jobsite, located at 1200 102nd Ave N Saint Petersburg, FL 33716; on or about 7/7/23, the employer exposed employees to struck by hazards, in that head protection was not used while conducting apartment balcony restoration operations with pneumatic nail guns, wood and hammers.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-09-14
Current Penalty 4018.0
Initial Penalty 4018.0
Final Order 2023-10-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: a.) At the jobsite, located at 1200 102nd Ave N Saint Petersburg, FL 33716; on or about 7/7/23, the employer exposed employees to struck by hazards, in that eye protection was not used while conducting apartment balcony restoration operations with pneumatic nail guns, circular saws and hammers.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1):Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports as follows: a.) At the jobsite, located at 1200 102nd Ave N Saint Petersburg, FL 33716; on or about 7/7/23, the employer exposed employees to fall hazards, in that employees were conducting apartment balcony restoration operations approximately 8 ft and 13 ft from a supported scaffold platform that was not fully planked on the 2nd and 3rd levels.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-11
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a.) At the jobsite, located at 1200 102nd Ave N Saint Petersburg, FL 33716; on or about 7/7/23, the employer exposed employees to fall hazards, in that employees were conducting apartment balcony restoration operations approximately 13 ft from a supported scaffold platform that did not contain fall protection on the 3rd level.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2023-09-14
Current Penalty 2679.0
Initial Penalty 2679.0
Final Order 2023-10-11
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a.) At the jobsite, located at 1200 102nd Ave N Saint Petersburg, FL 33716; on or about 7/7/23, the employer exposed employees to fall hazards,in that fall protection certification training records were not provided for employees conducting scaffolding operations at approximately 8ft. and 13ft. while conducting apartment balcony restoration operations.