Entity Name: | PRINCIPLE CONSTRUCTION LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PRINCIPLE CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 04 Jan 2019 (6 years ago) |
Date of dissolution: | 24 Sep 2021 (3 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 24 Sep 2021 (3 years ago) |
Document Number: | L19000006810 |
FEI/EIN Number |
APPLIED FOR
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 110 W PALMETTO RD, LAKE WORTH, FL, 33467, UN |
Mail Address: | 110 W PALMETTO RD, LAKE WORTH, FL, 33467, UN |
ZIP code: | 33467 |
County: | Palm Beach |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RODRIGUEZ JOSE N | Manager | 110 W PALMETTO RD, LAKE WORTH, FL, 33467 |
JOSE RODRIGUEZ LLC. | Agent | - |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2021-09-24 | - | - |
REINSTATEMENT | 2020-10-20 | - | - |
REGISTERED AGENT NAME CHANGED | 2020-10-20 | Jose Rodriguez | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2020-09-25 | - | - |
Name | Date |
---|---|
REINSTATEMENT | 2020-10-20 |
Florida Limited Liability | 2019-01-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338943152 | 0418800 | 2013-03-07 | 2390 SOUTH MILITARY TRAIL, WEST PALM BEACH, FL, 33415 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2013-04-01 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-04-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: On or about March 7, 2013, at the above addressed jobsite, an employee performing work picking up roofing materials directly under two other employees performing roof work was not wearing head protection equipment while exposed to potential struck by head injury. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2013-04-01 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-04-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: On or about March 7, 2013, at the above addressed jobsite: Employees performing roof work installing metal flashing on a steep roof with unprotected edges approximately 14 ft. above a lower level were not protected from falling to that lower level. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B08 |
Issuance Date | 2013-04-01 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-04-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On or about March 7, 2013, at the above addressed jobsite: Employees gaining access to and from a roof approximately 20 ft. above a lower level using an 28 ft. fiberglass extension ladder set up on an active parking lot and walkway did not have that ladder secured to prevent accidental displacement. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2008-08-08 |
Emphasis | L: FALL |
Case Closed | 2008-10-17 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2008-10-01 |
Abatement Due Date | 2008-10-06 |
Current Penalty | 750.0 |
Initial Penalty | 1000.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 03 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2008-08-07 |
Emphasis | L: FALL, S: FALL FROM HEIGHT |
Case Closed | 2008-09-17 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2008-09-03 |
Abatement Due Date | 2008-09-08 |
Current Penalty | 375.0 |
Initial Penalty | 375.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 03 |
Date of last update: 01 Mar 2025
Sources: Florida Department of State