Entity Name: | M & S PINK HILLTOP ROOFING LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
M & S PINK HILLTOP ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 10 Dec 2018 (6 years ago) |
Date of dissolution: | 27 Sep 2019 (6 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2019 (6 years ago) |
Document Number: | L18000282057 |
Address: | 6724 PRIDGEN STREET, PANAMA CITY, FL, 32404, US |
Mail Address: | 6724 PRIDGEN STREET, PANAMA CITY, FL, 32404, US |
ZIP code: | 32404 |
County: | Bay |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ROCHA QUINTANA SARHAY | Manager | 6724 PRIDGEN STREET, PANAMA CITY, FL, 32404 |
ROCHA QUINTANA SARHAY | Agent | 6724 PRIDGEN STREET, PANAMA CITY, FL, 32404 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
Name | Date |
---|---|
Florida Limited Liability | 2018-12-10 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343771671 | 0419700 | 2019-02-08 | 6317 LAKE JOANNE CIRCLE, PANAMA CITY, FL, 32405 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-06-10 |
Current Penalty | 3978.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-07-12 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a. On or about February 8, 2019 two employees removing old roof shingles from the first story of a 7:12 pitch residential roof, were not protected by means of personal fall protection, guardrails, or safety nets and were exposed to falls in excess of 9 feet to the ground below. b. On or about February 8, 2019 two employees removing old roof shingles from the second story of a 7:12 pitch residential roof, were not protected by means of personal fall protection, guardrails, or safety nets and were exposed to falls in excess of 13 feet to the ground below. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2019-06-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-07-12 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part. a. On or about February , 2019 the employer did not establish or maintain a Safety and Health Program for employees that covered the following basic elements of the standard. |
Date of last update: 02 Apr 2025