Entity Name: | 406 ROOFS LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
406 ROOFS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 27 Nov 2018 (6 years ago) |
Date of dissolution: | 25 Sep 2020 (5 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 25 Sep 2020 (5 years ago) |
Document Number: | L18000274363 |
FEI/EIN Number |
83-2643639
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 243 KAY AVE, WEWAHITCHKA, FL, 32465, US |
Mail Address: | 243 KAY AVE, WEWAHITCHKA, FL, 32465, US |
ZIP code: | 32465 |
County: | Gulf |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RUIZ CESAR SR | Manager | 732 LAUREN LANE, IMMOKALEE, FL, 34142 |
CRYAR CHARLES DJR. | Manager | 243 KAY AVE, WEWAHITCHKA, FL, 32465 |
RUIZ CESAR SR | Agent | 732 LAUREN LANE, IMMOKALEE, FL, 34142 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2020-09-25 | - | - |
LC AMENDMENT | 2019-02-14 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2019-02-14 | 243 KAY AVE, WEWAHITCHKA, FL 32465 | - |
CHANGE OF MAILING ADDRESS | 2019-02-14 | 243 KAY AVE, WEWAHITCHKA, FL 32465 | - |
Name | Date |
---|---|
LC Amendment | 2019-02-14 |
ANNUAL REPORT | 2019-01-25 |
Florida Limited Liability | 2018-11-27 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343777801 | 0419700 | 2019-02-12 | 200 8TH ST, MEXICO BEACH, FL, 32456 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2019-03-15 |
Current Penalty | 1363.8 |
Initial Penalty | 2273.0 |
Final Order | 2019-04-08 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On or about February 12, 2019, roofing employees using pneumatic nail guns to install fiberglass shingles were eposed to eye injury hazards from flying debris in that they were not wearing protective eyewear. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-03-15 |
Current Penalty | 2727.6 |
Initial Penalty | 4546.0 |
Final Order | 2019-04-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about February 12, 2019, on the 5:12 pitch roof, five roofing employees installing fiberglass shingles were exposed to an 11 feet fall hazard in that they were not protected by a fall protection system. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-03-15 |
Current Penalty | 2727.6 |
Initial Penalty | 4546.0 |
Final Order | 2019-04-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about February 12, 2019, at the eave above the garage, the roofing employees were exposed to a 12 feet fall hazard in that the roof access ladder was not extended at least 3 feet above the edge of the eave. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2019-03-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-04-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a On or about February 12, 2019, employees were exposed to a 12 feet fall hazard from the unsecured roof access ladder in that the ladder feet were placed flat on an unstable gravel surface. |
Date of last update: 01 Apr 2025