Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-07-06
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2023-10-23
|
Related Activity
Type |
Referral |
Activity Nr |
2047978 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100178 A04 |
Issuance Date |
2023-09-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly: On or about 7/06/2023, at 7975 NW 54 Street, Doral Fl 33166, forklifts with an attachment not approved by the manufacturer was being use to move material such as granite and quartz slabs at the shop area. |
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-06-29
|
Emphasis |
N: RCS-NEP
|
Case Closed |
2024-03-18
|
Related Activity
Type |
Referral |
Activity Nr |
2045872 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2023-08-25 |
Abatement Due Date |
2023-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Inspection NR |
1712988 |
FTA Issuance Date |
2024-01-29 |
FTA Current Penalty |
320.0 |
FTA Final Order Date |
2024-02-23 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about 06/29/2023 at 7975 NW 54th St. Doral, FL 33166, the employer did not develop and implement a written respiratory program for those employees required to wear respiratory protection, including 3M Half Facepiece Reusable Respirator 6300/07026 and Comfort Ease N95 AD2N95A filtering facepiece respirators while fabricating marble, corsite, porcelain, and quartz. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-08-25 |
Abatement Due Date |
2023-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Inspection NR |
1712988 |
FTA Issuance Date |
2024-01-29 |
FTA Current Penalty |
320.0 |
FTA Final Order Date |
2024-02-23 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. On or about 06/29/2023 at 7975 NW 54th St. Doral, FL 33166, the employer did not provide medical evaluations for employees who were required to wear 3M Half Facepiece Reusable Respirator 6300/07026 and Comfort Ease N95 AD2N95A filtering facepiece respirators while fabricating marble, corsite, porcelain, and quartz. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19101053 D01 |
Issuance Date |
2023-08-25 |
Abatement Due Date |
2023-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1053(d)(1): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section: On or about 06/29/2023 at 7975 NW 54th St. Doral, FL 33166, the employer did not ensure initial monitoring was performed to determine each employee's exposure to respirable crystalline silica while fabricating marble, corsite, porcelain, and quartz. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2023-08-25 |
Abatement Due Date |
2023-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Inspection NR |
1712988 |
FTA Issuance Date |
2024-01-29 |
FTA Current Penalty |
320.0 |
FTA Final Order Date |
2024-02-23 |
Citation text line |
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met: On or about 06/29/2023 at 7975 NW 54th St. Doral, FL 33166, the employer did not develop, implement, and maintain at the workplace a written hazard communication program where employees were exposed to hazardous chemicals including, but not limited to, GE500 silicone sealant, acetone, DOMOCOMB A+B epoxy glue, and muriatic acid while fabricating and installing stone. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2023-08-25 |
Abatement Due Date |
2023-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Inspection NR |
1712988 |
FTA Issuance Date |
2024-01-29 |
FTA Current Penalty |
320.0 |
FTA Final Order Date |
2024-02-23 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): On or about 06/29/2023 at 7975 NW 54th St. Doral, FL 33166, the employer did not ensure effective measures for communication about hazardous chemical information to employees due to not maintaining copies of safety data sheets for every hazardous chemical in the workplace including, but not limited to, GE500 silicone sealant, acetone, DOMOCOMB A+B epoxy, and muriatic acid, and not ensuring all safety data sheets were readily accessible to employees who use these while fabricating stone. |
|
|