Entity Name: | CENTRAL FLORIDA EQUITY BUILDERS, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
CENTRAL FLORIDA EQUITY BUILDERS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 06 Sep 2018 (7 years ago) |
Document Number: | L18000212759 |
FEI/EIN Number |
83-1819068
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2582 Connection Pt., Suite 1008, Oviedo, FL, 32765, US |
Mail Address: | 2582 Connection Pt., Suite 1008, Oviedo, FL, 32765, US |
ZIP code: | 32765 |
County: | Seminole |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
WILSON RHETT | Manager | 2582 Connection Pt., Oviedo, FL, 32765 |
Petrow Edward V | Manager | 2582 Connection Pt., Oviedo, FL, 32765 |
Petrow Edward VCEO | Agent | 2582 Connection Pt., Oviedo, FL, 32765 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2024-02-20 | Petrow, Edward V, CEO | - |
CHANGE OF PRINCIPAL ADDRESS | 2023-01-05 | 2582 Connection Pt., Suite 1008, Oviedo, FL 32765 | - |
CHANGE OF MAILING ADDRESS | 2023-01-05 | 2582 Connection Pt., Suite 1008, Oviedo, FL 32765 | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-01-05 | 2582 Connection Pt., Suite 1008, Oviedo, FL 32765 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-29 |
ANNUAL REPORT | 2024-02-20 |
ANNUAL REPORT | 2023-01-05 |
ANNUAL REPORT | 2022-03-02 |
ANNUAL REPORT | 2021-06-08 |
ANNUAL REPORT | 2020-07-01 |
ANNUAL REPORT | 2019-03-28 |
Florida Limited Liability | 2018-09-06 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347894735 | 0419730 | 2024-11-21 | 739 ELLWOOD AVE, ORLANDO, FL, 32804 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-12-06 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2025-01-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 21, 2024, at the jobsite: employees were exposed to a 23 foot fall hazard while working on the flat roof, in that, fall protection was not used. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-12-06 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2025-01-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about November 21, 2024, at the jobsite: employees were exposed to a 23 foot fall hazard while accessing the flat roof, in that, the ladder side rails only extended approximately 18" inches passed the roof landing. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2024-12-06 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2025-01-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) On or about November 21, 2024, at the jobsite: employees were exposed to 23 foot fall hazards while ascending ladders and carrying 4' X 8' recovery fiber boards, in that employees could lose balance while not maintaining 3 points of contact on the ladder. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-12-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2025-01-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record. a. On or about November 21, 2024, at the jobsite: the employer did not provide written fall protection training certificates for employees exposed to an approximate 23 foot fall hazard while working on a flat roof. |
Status | User ID | Name of Firm | Trade Name | UEI | Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Active | P3172871 | CENTRAL FLORIDA EQUITY BUILDERS, LLC | CENTRAL FLORIDA EQUITY BUILDERS LLC | JG7WD3J9GXZ1 | 2582 CONNECTION PT STE 1008, OVIEDO, FL, 32765-5007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HUBZone Certified | No |
Women Owned Certified | No |
Women Owned Pending | No |
Economically Disadvantaged Women Owned Certified | No |
Economically Disadvantaged Women Owned Pending | No |
Veteran-Owned Small Business Certified | No |
Veteran-Owned Small Business Joint Venture | No |
Service-Disabled Veteran-Owned Small Business Certified | Yes |
Service-Disabled Veteran-Owned Small Business Joint Venture | No |
Service-Disabled Veteran-Owned Small Business Certification Date | 2024-05-15 |
Service-Disabled Veteran-Owned Small Business Certification Expiration Date | 2028-05-15 |
Bonding Levels
Description | Construction Bonding Level (per contract) |
Level | (none given) |
Description | Construction Bonding Level (aggregate) |
Level | (none given) |
Description | Service Bonding Level (per contract) |
Level | (none given) |
Description | Service Bonding Level (aggregate) |
Level | (none given) |
NAICS Codes with Size Determinations by NAICS
Primary | Yes |
Code | 238160 |
NAICS Code's Description | Roofing Contractors |
Buy Green | Yes |
Code | 236115 |
NAICS Code's Description | New Single-family Housing Construction (Except For-Sale Builders) |
Buy Green | Yes |
Code | 238130 |
NAICS Code's Description | Framing Contractors |
Buy Green | Yes |
Export Profile (Trade Mission Online)
Exporter | Firm hasn't answered this question yet |
Export Business Activities | (none given) |
Exporting to | (none given) |
Desired Export Business Relationships | (none given) |
Description of Export Objective(s) | (none given) |
Date of last update: 03 Apr 2025
Sources: Florida Department of State