Search icon

NAR ROOFING LLC

Company Details

Entity Name: NAR ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Active
Date Filed: 26 Jul 2018 (7 years ago)
Last Event: LC AMENDMENT
Event Date Filed: 23 Oct 2023 (a year ago)
Document Number: L18000180029
FEI/EIN Number 83-1462671
Address: 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135
Mail Address: 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135
ZIP code: 34135
County: Lee
Place of Formation: FLORIDA

Agent

Name Role Address
CATIVO FLORES, DAVID FERNANDO Agent 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135

Authorized Member

Name Role Address
CATIVO, BLANCA Authorized Member 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135
Cativo Flores, David Fernando Authorized Member 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-04-17 CATIVO FLORES, DAVID FERNANDO No data
LC AMENDMENT 2023-10-23 No data No data
LC AMENDMENT 2023-10-10 No data No data
CHANGE OF PRINCIPAL ADDRESS 2022-02-04 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135 No data
CHANGE OF MAILING ADDRESS 2020-06-24 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135 No data
REGISTERED AGENT ADDRESS CHANGED 2020-06-24 24377 GOLDEN EAGLE LANE, BONITA SPRINGS, FL 34135 No data

Documents

Name Date
ANNUAL REPORT 2025-01-22
AMENDED ANNUAL REPORT 2024-04-17
ANNUAL REPORT 2024-03-13
LC Amendment 2023-10-23
LC Amendment 2023-10-10
ANNUAL REPORT 2023-03-07
AMENDED ANNUAL REPORT 2022-05-24
ANNUAL REPORT 2022-02-04
ANNUAL REPORT 2021-01-27
ANNUAL REPORT 2020-06-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347626426 0420600 2024-07-17 2527 RIVERBLUFF PKWY, SARASOTA, FL, 34231
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-07-17
Emphasis N: FALL

Related Activity

Type Inspection
Activity Nr 1762581
Safety Yes
Type Complaint
Activity Nr 2186513
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2024-07-25
Abatement Due Date 2024-08-20
Current Penalty 5071.0
Initial Penalty 5071.0
Final Order 2024-08-20
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a. On or about Month July 17, 2024, at 2527 Riverbluff Pkwy, Sarasota, FL 34231, employees were engaged in roofing work; wherein the employees were removing and then reinstalling roofing materials on a low-slope roof, less than 50 feet in width, with unprotected sides and edges 6 feet or more above lower levels, during which time the employer had not prepared a written certification of training for each employee; therefore exposing the employees to a fall hazard.
344308044 0419700 2019-09-12 1120 N. 15TH ST, MEXICO BEACH, FL, 32456
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-09-12
Emphasis L: FALL, P: FALL
Case Closed 2022-06-10

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B10
Issuance Date 2019-11-18
Current Penalty 10608.0
Initial Penalty 10608.0
Final Order 2020-01-07
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a. On or about September 12, 2019, on the south slope of the roof, three roofing employees installing components for a sheet metal roof were exposed to a 26 feet fall hazard in that they were not protected by a fall protection system. NAR Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1393407, Serious citation number 1, item number 2 and was affirmed as a final order on August 26, 2019, with respect to a workplace located at 300 Ryders Cup Circle, Saint Augustine, florida.
343934071 0419700 2019-04-11 300 RYDERS CUP CIRCLE, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-05-30
Emphasis L: FALL, P: FALL
Case Closed 2022-07-28

Related Activity

Type Inspection
Activity Nr 1393399
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-06-26
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-08-26
Nr Instances 2
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about April 9, 2019 to April 11, 2019: Two employees were observed operating pneumatic nail gun on building 115 while installing roof shingles and were not using eye protection, exposing employees to eye injuries. b) On or about April 9, 2019: Two employees were observed operating pneumatic nail gun on building 230 while installing roof shingles and were not using eye protection, exposing employees to eye injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-06-26
Current Penalty 9282.0
Initial Penalty 9282.0
Final Order 2019-08-26
Nr Instances 3
Nr Exposed 30
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 9, 2019 to April 11, 2019: Employees were observed performing roofing activities on building 115 and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing employees to 9 to 28-feet fall hazard. b) On or about April 9, 2019 to April 11, 2019: Employees were observed performing roofing activities on building 230 and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing employees to 9 to 28-feet fall hazard. c) On or about April 9, 2019 to April 11, 2019: Employees were observed performing roofing activities on building 300 and were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection; exposing employees to 9 to 28-feet fall hazard.

Date of last update: 17 Feb 2025