Entity Name: | OGBURN'S TREE SERVICE LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
OGBURN'S TREE SERVICE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 12 Jun 2018 (7 years ago) |
Date of dissolution: | 24 Sep 2021 (4 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 24 Sep 2021 (4 years ago) |
Document Number: | L18000144347 |
FEI/EIN Number |
85-4365440
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1575 Canopy Ln, Orange City, FL, 32763, US |
Mail Address: | 1575 Canopy Ln, Orange City, FL, 32763, US |
ZIP code: | 32763 |
County: | Volusia |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
OGBURN JAZZIMANE L | Authorized Member | 1575 Canopy Ln, Orange City, FL, 32763 |
ogburn JAZZIMANE L | Agent | 1575 Canopy Ln, Orange City, FL, 32763 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2021-09-24 | - | - |
REINSTATEMENT | 2020-12-21 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2020-12-21 | 1575 Canopy Ln, Apt 305, Orange City, FL 32763 | - |
REGISTERED AGENT ADDRESS CHANGED | 2020-12-21 | 1575 Canopy Ln, Apt 305, Orange City, FL 32763 | - |
CHANGE OF MAILING ADDRESS | 2020-12-21 | 1575 Canopy Ln, Apt 305, Orange City, FL 32763 | - |
REGISTERED AGENT NAME CHANGED | 2020-12-21 | ogburn, JAZZIMANE L | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
Name | Date |
---|---|
REINSTATEMENT | 2020-12-21 |
Florida Limited Liability | 2018-06-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343232765 | 0419700 | 2018-06-18 | 2524 COCOA AVENUE, PANAMA CITY, FL, 32405 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Accident |
Activity Nr | 1349076 |
Violation Items
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100333 C03 I A |
Issuance Date | 2018-10-10 |
Current Penalty | 5000.0 |
Initial Penalty | 12934.0 |
Contest Date | 2018-12-17 |
Final Order | 2020-01-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.333(c)(3)(i)(A): The employer did not insure that when an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances, exposing employees to the risk of injuries caused by contacting energized current carrying parts. These may include electric shock, severe burns, and electrocution. [1] For voltages to ground 50kV or below 10 ft. (305 cm); a. On or about June 15, 2018, an employee trimming tree from an Haulotte aerial lift with 14 foot parkland pole saw, was within 10 feet of a 7200 volt-single phase overhead power line system, exposed to an electrocution hazard. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100067 C02 II |
Issuance Date | 2018-10-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2018-12-17 |
Final Order | 2020-01-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Accident |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.67(c)(2)(ii): An employee(s) operating an aerial lift(s) was not properly trained: a. On or about June 15, 2018, an employee operating a Haulotte aerial lift was not trained to operate the equipment, exposing the employee to a falling/crushing hazard. |