Search icon

CASA ROOFING LLC - Florida Company Profile

Company Details

Entity Name: CASA ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CASA ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 31 May 2018 (7 years ago)
Document Number: L18000135970
FEI/EIN Number 83-0730428

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7002 DAVIS CREEK RD, JACKSONVILLE, FL, FL, 32256, US
Mail Address: PO Box 56726, Jacksonville, FL, 32241, US
ZIP code: 32256
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
THE GABY GROUP LLC Manager -
FARMAND CHRIS Agent 9310 OLD KINGS ROAD, JACKSONVILLE, FL, 32257

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-03-28 7002 DAVIS CREEK RD, JACKSONVILLE, FL, FL 32256 -
CHANGE OF MAILING ADDRESS 2024-03-28 7002 DAVIS CREEK RD, JACKSONVILLE, FL, FL 32256 -

Documents

Name Date
ANNUAL REPORT 2025-01-29
ANNUAL REPORT 2024-03-28
ANNUAL REPORT 2023-03-21
ANNUAL REPORT 2022-02-15
ANNUAL REPORT 2021-02-04
ANNUAL REPORT 2020-01-27
ANNUAL REPORT 2019-02-13
Florida Limited Liability 2018-05-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347874349 0419700 2024-11-13 66 ERLKING COURT LOT 226, SAINT JOHNS, FL, 32259
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-11-13
Emphasis N: FALL, P: FALL
Case Closed 2025-01-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-11-18
Current Penalty 1350.0
Initial Penalty 2074.0
Final Order 2024-12-19
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. a. On top of a structure located at 66 Erlking Court, LOT 236, Saint Johns, FL: On or about November 13, 2024, the employer exposed employees to struck-by hazards, in that an employee was not wearing safety glasses while using a pneumatic nail gun.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-11-18
Current Penalty 2700.0
Initial Penalty 4148.0
Final Order 2024-12-19
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On top of a residential structure located at 66 Erlking Court, Saint Johns, FL: On or about November 13, 2024, the employer exposed employees to fall hazard, in that fall protection was not utilized by employees performing roofing operations.
Citation ID 02001
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2024-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-12-19
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. Positioned in the front of a residential structure located at 66 Erlking Court, Saint Johns, FL: On or about November 13, 2024, the employer exposed employees to fall hazards, in that a 16-foot Gorilla Little Giant ladder was used to access the top of the structure and did not extend three feet above the eave as required.

Date of last update: 01 Apr 2025