Search icon

METALTEK LLC - Florida Company Profile

Company Details

Entity Name: METALTEK LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

METALTEK LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 06 Apr 2018 (7 years ago)
Last Event: LC AMENDMENT AND NAME CHANGE
Event Date Filed: 18 Oct 2024 (5 months ago)
Document Number: L18000085469
FEI/EIN Number 825110361

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2853 KIRBY CIR NE, PALM BAY, FL, 32905, US
Mail Address: 1088 WELCH RD. SE, PALM BAY, FL, 32909, US
ZIP code: 32905
County: Brevard
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MARCELLA CORY Manager 2526 S. HARBOR CITY BLVD., MELBOURE, FL, 32901
MARCELLA CORY M Agent 2853 KIRBY CIR NE, PALM BAY, FL, 32905

Events

Event Type Filed Date Value Description
LC AMENDMENT AND NAME CHANGE 2024-10-18 SMITTY'S WELDING AND SHEET METAL FABRICATION LLC -
CHANGE OF PRINCIPAL ADDRESS 2024-10-18 2853 KIRBY CIR NE, UNIT 738, PALM BAY, FL 32905 -
CHANGE OF MAILING ADDRESS 2024-10-18 2853 KIRBY CIR NE, UNIT 738, PALM BAY, FL 32905 -
REGISTERED AGENT NAME CHANGED 2024-10-18 MARCELLA, CORY MICHAEL -
LC NAME CHANGE 2023-08-28 METALTEK LLC -
LC AMENDMENT 2018-05-10 - -
LC NAME CHANGE 2018-04-25 SMITTY'S WELDING AND SHEET METAL FABRICATION, LLC -

Documents

Name Date
LC Amendment and Name Change 2024-10-18
ANNUAL REPORT 2024-04-29
LC Name Change 2023-08-28
ANNUAL REPORT 2023-01-23
ANNUAL REPORT 2022-04-29
ANNUAL REPORT 2021-04-14
ANNUAL REPORT 2020-01-20
ANNUAL REPORT 2019-04-02
LC Amendment 2018-05-10
LC Name Change 2018-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340640986 0420600 2015-05-12 4121 DRAIN FIELD ROAD, LAKELAND, FL, 33811
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-05-14
Emphasis L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2015-10-27

Related Activity

Type Referral
Activity Nr 981581
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 II B
Issuance Date 2015-07-24
Abatement Due Date 2015-10-23
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2015-08-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a.) In the production area, machine specific lockout procedures for the Accurpress hydraulic press brake (model #732012) did not include the procedural steps for die-setting, on or about May 25, 2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100217 E01 I
Issuance Date 2015-07-24
Current Penalty 0.0
Initial Penalty 4900.0
Final Order 2015-08-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: (a) Production Area - the employer did not have a maintenance program to include, but not limited to the Accurpress Model#732012, exposing employees to an amputation hazard, on or about May 25, 2015.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2015-07-24
Abatement Due Date 2015-10-23
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2015-08-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: a.) In the production area, machine specific lock out training to include die-setting on the Accurpress hydraulic press brake (model #732012) was not provided by the employer, on or about May 25, 2015.