Search icon

A&A LINAS GRANITE LLC - Florida Company Profile

Company Details

Entity Name: A&A LINAS GRANITE LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

A&A LINAS GRANITE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 28 Mar 2018 (7 years ago)
Date of dissolution: 03 Aug 2022 (3 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 03 Aug 2022 (3 years ago)
Document Number: L18000079133
FEI/EIN Number 824957478

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL, 32084, US
Mail Address: 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL, 32084, US
ZIP code: 32084
County: St. Johns
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MEDEIROS ANGELINA Manager 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL, 32084
Freedman Barry Auth 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL, 32084
MEDEIROS AVELINO Agent 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL, 32084

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2022-08-03 - -
REGISTERED AGENT NAME CHANGED 2021-03-16 MEDEIROS, AVELINO -
LC AMENDMENT 2018-09-19 - -
CHANGE OF PRINCIPAL ADDRESS 2018-09-19 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL 32084 -
CHANGE OF MAILING ADDRESS 2018-09-19 1700 N PONCE DE LEON BLVD, ST AUGUSTINE, FL 32084 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J22000009581 ACTIVE 1000000911816 ST JOHNS 2021-12-23 2042-01-05 $ 6,103.75 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J21000121883 ACTIVE 1000000880611 ST JOHNS 2021-03-15 2041-03-17 $ 10,808.57 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J21000039846 ACTIVE 1000000874740 ST JOHNS 2021-01-25 2041-01-27 $ 99,127.54 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J19000780476 ACTIVE 1000000849613 ST JOHNS 2019-11-21 2039-11-27 $ 20,070.64 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J19000684173 TERMINATED 1000000844157 ST JOHNS 2019-10-10 2039-10-16 $ 6,924.13 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J19000396570 TERMINATED 1000000828179 ST JOHNS 2019-05-28 2039-06-05 $ 16,120.15 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825

Documents

Name Date
VOLUNTARY DISSOLUTION 2022-08-03
AMENDED ANNUAL REPORT 2021-05-10
ANNUAL REPORT 2021-03-16
ANNUAL REPORT 2020-06-24
ANNUAL REPORT 2019-02-14
LC Amendment 2018-09-19
Florida Limited Liability 2018-03-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344896345 0419700 2020-08-25 1700 N. PONCE DE LEON BLVD., SAINT AUGUSTINE, FL, 32084
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2020-08-25
Emphasis N: RCS-NEP
Case Closed 2020-09-08

Related Activity

Type Inspection
Activity Nr 1437867
Health Yes
344378674 0419700 2019-10-15 1700 N. PONCE DE LEON BLVD., SAINT AUGUSTINE, FL, 32084
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2019-10-16
Case Closed 2023-04-05

Related Activity

Type Inspection
Activity Nr 1437923
Health Yes
Type Complaint
Activity Nr 1505849
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101053 C
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 885.0
Initial Penalty 1475.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(c): The employer did not ensure that no employee was exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m3, calculated as an 8-hour TWA: a. A fabricator dry cutting granite in the Fabrication Area was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 82.5 micrograms per cubic meter (µg/m3), 1.6 times the permissible exposure limit of 50.0 µg/m3. The sampling was performed for 168 minutes on October 16, 2019.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101053 F01
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(f)(1): The employer did not use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible: a. A fabricator dry cutting granite in the Fabrication Area was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 82.5 micrograms per cubic meter (µg/m3), 1.6 times the permissible exposure limit of 50.0 µg/m3. The sampling was performed for 168 minutes on October 16, 2019. The employer failed to implement any engineering or work practice control methods for this task.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101053 G02
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(g)(2): Where respirator use was required by this section, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134: a. A fabricator dry cutting granite in the Fabrication Area was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 82.5 micrograms per cubic meter (µg/m3), 1.6 times the permissible exposure limit of 50.0 µg/m3. The sampling was performed for 168 minutes on October 16, 2019. The employer did not develop and institute a respiratory protection program.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about October 15, 2019, an employee who wore a NIOSH approved 3M respirator while dry cutting granite in the Fabrication Area had not been provided with medical evaluation prior to wearing the respirator.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about October 15, 2019, an employee who wore a NIOSH approved 3M respirator while dry cutting granite in the Fabrication Area had not been fit tested prior to initial use of the respirator.
Citation ID 01001F
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a. On or about October 15, 2019, an employee who wore a NIOSH approved 3M respirator while dry cutting granite in the Fabrication Area had not received respirator training.
Citation ID 01002
Citaton Type Serious
Standard Cited 19101053 E01
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 885.0
Initial Penalty 1475.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(e)(1): The employer did not establish a regulated area wherever an employee's exposure to airborne concentrations of respirable crystalline silica was, or could have been reasonably expected to be, in excess of the PEL: a. A fabricator dry cutting granite in the Fabrication Area was exposed to Respirable Crystalline Silica at a Time Weighted Average (TWA) of 82.5 micrograms per cubic meter (µg/m3), 1.6 times the permissible exposure limit of 50.0 µg/m3. The sampling was performed for 168 minutes on October 16, 2019. The employer did not establish a regulated area.
Citation ID 01003
Citaton Type Serious
Standard Cited 19101053 F02 I
Issuance Date 2020-02-14
Abatement Due Date 2020-04-02
Current Penalty 885.0
Initial Penalty 1475.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1053(f)(2)(i): The employer did not establish and implement a written exposure control plan: a. On or about October 16, 2019, an employee was exposed to respirable crystalline silica above the permissible exposure limit when dry cutting on granite and the employer had not established and implemented a written silica exposure control plan.
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2020-02-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-09
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about October 15, 2019, fabrication shop, extension cords providing current to fans hanging from the ceiling area were being used as permanent wiring and strung against the ceiling.
343538948 0419700 2018-10-17 1700 N. PONCE DE LEON BLVD., SAINT AUGUSTINE, FL, 32084
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2018-10-17
Case Closed 2019-05-01

Related Activity

Type Complaint
Activity Nr 1390782
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 L
Issuance Date 2019-01-29
Abatement Due Date 2019-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a. On or about August 31, 2018, in the fabrication area, the employer did not train the forklift operators to ensure they were competent to safely operate a "Komatsu 25" powered industrial truck.
Citation ID 01002A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2019-01-29
Abatement Due Date 2019-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-25
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about October 17, 2018, in the fabrication area, the employer failed to develop, implement and maintain a written Hazard Communication Program for the protection of the employees using hazardous chemicals, including but not limited to Acetone and Polyester Stone Adhesive.
Citation ID 01002B
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2019-01-29
Abatement Due Date 2019-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a. On or about October 17, 2018, in the fabrication area, the employer did not have a copy of the Safety Data Sheets (SDS) of all the hazardous chemicals stored and used in the workplace for the information and protection of the employees using such chemicals, including but not limited to Acetone and Polyester Stone Adhesive.
Citation ID 01002C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2019-01-29
Abatement Due Date 2019-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about October 17, 2018, in the fabrication area, the employer failed to provide training on Hazard Communication for the protection of the employees using hazardous chemicals, including but not limited to Acetone and Polyester Stone Adhesive.

Date of last update: 01 Apr 2025

Sources: Florida Department of State