Search icon

ALL COAST ROOFING LLC - Florida Company Profile

Company Details

Entity Name: ALL COAST ROOFING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ALL COAST ROOFING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Mar 2018 (7 years ago)
Document Number: L18000060253
FEI/EIN Number 824679953

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3379 APPALACHIAN DR, BROOKSVILLE, FL, 34602, US
Mail Address: 3379 APPALACHIAN DR, BROOKSVILLE, FL, 34602, US
ZIP code: 34602
County: Hernando
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WALTERS CHRISTOPHER M Manager 3379 APPALACHIAN DR, BROOKSVILLE, FL, 34602
WALTERS RICK A Manager 16932 HELEN K DR, SPRING HILL, FL, 34610
Hoogewind Joel A Manager 7255 Griffin Rd, Brooksville, FL, 34601
WALTERS CHRISTOPHER M Agent 3379 APPALACHIAN DR, BROOKSVILLE, FL, 34602

Events

Event Type Filed Date Value Description
CHANGE OF MAILING ADDRESS 2019-02-11 3379 APPALACHIAN DR, BROOKSVILLE, FL 34602 -
REGISTERED AGENT ADDRESS CHANGED 2019-02-11 3379 APPALACHIAN DR, BROOKSVILLE, FL 34602 -

Documents

Name Date
ANNUAL REPORT 2025-02-07
ANNUAL REPORT 2024-01-10
ANNUAL REPORT 2023-01-23
ANNUAL REPORT 2022-01-04
ANNUAL REPORT 2021-01-19
ANNUAL REPORT 2020-01-14
ANNUAL REPORT 2019-02-11
Florida Limited Liability 2018-03-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345687396 0420600 2021-12-15 18820 CORTEZ BLVD., BROOKSVILLE, FL, 34601
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2022-05-23
Emphasis L: FALL
Case Closed 2022-07-21

Related Activity

Type Accident
Activity Nr 1843248

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 A02
Issuance Date 2022-05-31
Current Penalty 1595.35
Initial Penalty 5801.0
Final Order 2022-06-27
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(a)(2): Employees were allowed to work on surfaces which did not have the requisite strength and structural integrity:(a) a. 18820 Cortez Blvd., Brooksville, Florida, On or about December 13, 2021, employees were exposed to fall hazards of more than 20-feet while installing a new Thermoplastic Polyolefin (TPO) roof covering system over the existing Purlin Bearing Rib (PBR) metal panels and skylight type corrugated fiberglass panels, in that, the employer did not make an adequate determination on the strength and structural integrity of the existing roofing system to ensure it was capable of supporting employees.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2022-05-31
Current Penalty 11601.6
Initial Penalty 14502.0
Final Order 2022-06-27
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a. 18820 Cortez Blvd., Brooksville, Florida, On or about December 13, 2021, employees were exposed to fall hazards of more than 20-feet while installing a new Thermoplastic Polyolefin (TPO) roof covering system over the existing Purlin Bearing Rib (PBR) metal panels and skylight type corrugated fiberglass panels. The roof had a 1:12 pitch; 20-feet to the eave and 25-feet to the center top. Fall protection equipment was not installed or utilized nor were covers placed over the fiberglass panels to prevent employees from falling.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2022-05-31
Abatement Due Date 2022-06-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-06-27
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. 18820 Cortez Blvd., Brooksville, Florida, On or about December 13, 2021, the employer did not have fall protection certification for employees in the process of roofing activities.