Search icon

AGUILA CONTRACTOR, LLC - Florida Company Profile

Company Details

Entity Name: AGUILA CONTRACTOR, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

AGUILA CONTRACTOR, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Jan 2018 (7 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: L18000017319
FEI/EIN Number 82-4116531

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 114 SAN BLAS AVE, KISSIMMEE, FL, 34743, US
Mail Address: 114 SAN BLAS AVE, KISSIMMEE, FL, 34743, US
ZIP code: 34743
County: Osceola
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
AVILES VARGAS HECTOR L President 114 SAN BLAS AVE, KISSIMMEE, FL, 34743
AVILES VARGAS HECTOR L Agent 114 SAN BLAS AVE, KISSIMMEE, FL, 34743

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2023-06-05 114 SAN BLAS AVE, KISSIMMEE, FL 34743 -
CHANGE OF MAILING ADDRESS 2023-06-05 114 SAN BLAS AVE, KISSIMMEE, FL 34743 -
REGISTERED AGENT NAME CHANGED 2023-06-05 AVILES VARGAS, HECTOR L -
REGISTERED AGENT ADDRESS CHANGED 2023-06-05 114 SAN BLAS AVE, KISSIMMEE, FL 34743 -
LC AMENDMENT 2018-07-31 - -

Documents

Name Date
ANNUAL REPORT 2023-06-05
ANNUAL REPORT 2022-04-21
ANNUAL REPORT 2021-04-16
ANNUAL REPORT 2020-04-02
AMENDED ANNUAL REPORT 2019-07-12
ANNUAL REPORT 2019-03-04
LC Amendment 2018-07-31
Florida Limited Liability 2018-01-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344722921 0420600 2019-11-23 2404 METFIELD DR., MELBOURNE, FL, 32940
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-04-30
Emphasis L: FALL, P: FALL
Case Closed 2023-09-18

Related Activity

Type Inspection
Activity Nr 1447025
Safety Yes
Type Inspection
Activity Nr 1447010
Safety Yes
Type Inspection
Activity Nr 1447030
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260251 A01
Issuance Date 2020-05-08
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-06-05
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe: a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities were exposed to a struck by hazard, in that, four landscape timbers used as rigging to lift a 10,000 pound roof section were not inspected.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261425 B
Issuance Date 2020-05-08
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-06-05
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(b): While the operator was not moving the suspended load, no employee shall be within the fall zone, except those employees engaged in; (b)(1): hooking, unhooking or guiding a load; (b)(2) initial attachment of the load to a component or structure or (b)(3) operating a concrete hopper or bucket. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, the employees were working directly beneath a suspended 10,000 pound, 32' 3" by 32' 3" roof section attaching braces.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261425 C01
Issuance Date 2020-05-08
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-06-05
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(1): The employer did not make sure that the materials being hoisted when employees were hooking, unhooking, or guiding the load were rigged to prevent unintentional displacement. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, four landscape timbers were used as rigging to lift a 10,000 pound roof section. Landscape timbers were run along the top chord of cold steel formed metal trusses with no rigging securely holding the roof section in place.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261425 C03
Issuance Date 2020-05-08
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-06-05
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(3): The materials were not rigged by a qualified rigger. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, the load was not rigged by a qualified rigger.
344292040 0420600 2019-08-29 28463 PICANA LANE, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-08-29
Emphasis P: FALL, L: FALL
Case Closed 2022-12-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-01-15
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2020-02-20
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) roof - employees were exposed to a fall of approximately 18 feet while installing the roof deck and trusses, on or about 8/29/19.
344234901 0420600 2019-08-08 28724 REVARO LANE, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-08-08
Emphasis P: FALL, L: FALL
Case Closed 2022-12-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-01-15
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2020-02-20
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) roof above garage - employees were exposed to a fall of 9 feet 4 inches while installing lathe, on or about 8/8/19.

Date of last update: 03 Apr 2025

Sources: Florida Department of State