Entity Name: | SINCLAIR HOMES LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
SINCLAIR HOMES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 04 Dec 2017 (7 years ago) |
Date of dissolution: | 25 Nov 2019 (5 years ago) |
Last Event: | CONVERSION |
Event Date Filed: | 25 Nov 2019 (5 years ago) |
Document Number: | L17000247665 |
FEI/EIN Number |
82-3695994
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 6840 DABNEY ST, FORT MYERS, FL, 33966 |
Mail Address: | 3904 Whitehead Blvd, Panama City, FL, 32404, US |
ZIP code: | 33966 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SINCLAIR J DANIEL | Manager | 6840 DABNEY STREET, FORT MYERS, FL, 33966 |
SINCLAIR JAMES D | Agent | 6840 DABNEY STREET, FORT MYERS, FL, 33966 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CONVERSION | 2019-11-25 | - | CONVERSION MEMBER. RESULTING CORPORATION WAS P19000086938. CONVERSION NUMBER 100000197791 |
CHANGE OF MAILING ADDRESS | 2019-03-09 | 6840 DABNEY ST, FORT MYERS, FL 33966 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2019-03-09 |
ANNUAL REPORT | 2018-03-08 |
Florida Limited Liability | 2017-12-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344168240 | 0419700 | 2019-07-17 | 1302 HWY 306 BUSINESS BAYOU POINT VILLAS, PANAMA CITY, FL, 32405 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2019-08-21 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-09-13 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about July 17, 2019, three employees in the lift were not wearing body belts and lanyards attached to the basket, being exposed to fall hazards. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2019-08-21 |
Abatement Due Date | 2019-09-03 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-09-13 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by a guardrail system, safety net system or personal fall arrest system: a. On or about July 17, 2019, roof area, employees installing a metal roof system were not being protected from falling up to a 20 feet fall hazard by the use of a fall protection system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-08-21 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-09-13 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. On or about July 17, 2019, roof area, employees were using a Gorilla ladder to install trim. The ladder was not extended 3 feet past the landing and was not tied off to prevent accidental displacement, exposing employees to fall hazards. b. On or about July 17, 2019, stairs, employees were using a Gorilla ladder to gain access and egress from the roof. The ladder was not extended 3 feet past the landing and was not tied off to prevent accidental displacement, exposing employees to fall hazards. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2019-08-21 |
Current Penalty | 1705.2 |
Initial Penalty | 2842.0 |
Final Order | 2019-09-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about July 17, 2019, roof area, the employee stood on top step of the Gorilla ladder and was being exposed to fall hazards. |
Date of last update: 02 Mar 2025