Entity Name: LANDMARK DRYWALL & PAINTING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

LANDMARK DRYWALL & PAINTING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 22 Nov 2017 (7 years ago)
Date of dissolution: 28 Sep 2018 (7 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 28 Sep 2018 (7 years ago)
Document Number: L17000241180
Address: 507 EAST STREET, LONGWOOD, FL, 32750
Mail Address: 507 EAST STREET, LONGWOOD, FL, 32750
ZIP code: 32750
County: Seminole
Place of Formation: FLORIDA

Links between entities

Type Company Name Company Number State
Headquarter of LANDMARK DRYWALL & PAINTING LLC, MISSISSIPPI 954643 MISSISSIPPI
Headquarter of LANDMARK DRYWALL & PAINTING LLC, ALABAMA 000-613-079 ALABAMA

Key Officers & Management

Name Role Address
INGLE GARY S Manager 507 EAST STREET, LONGWOOD, FL, 32750
INGLE GARY S Agent 507 EAST STREET, LONGWOOD, FL, 32750

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -

Documents

Name Date
Florida Limited Liability 2017-11-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339157885 0419700 2013-06-25 601 SOUTH COPELAND, TALLAHASSEE, FL, 32304
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2013-06-27
Emphasis L: FALL
Case Closed 2018-09-19

Related Activity

Type Complaint
Activity Nr 824793
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2013-07-15
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-08-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about June 25, 2013, on the east side of the building, employees unloading siding material from the elevated platform were not wearing hard hats, exposing themselves to an overhead hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B03
Issuance Date 2013-07-15
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-08-20
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems: a. On or about June 25, 2013, on the north side of the building employees landing material from the thrid floor balcony were not protected from a 33-foot fall hazard by the use of a fall protection system. b. On or about June 25, 2013, on the north side of the building employees landing material from the fourth floor balcony were not protected from a 44-foot fall hazard by the use of a fall protection system.

Date of last update: 01 Apr 2025