Entity Name: | PHOENIX CONSTRUCTION GROUP II, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PHOENIX CONSTRUCTION GROUP II, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 09 Nov 2017 (7 years ago) |
Date of dissolution: | 27 Sep 2024 (7 months ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2024 (7 months ago) |
Document Number: | L17000232573 |
FEI/EIN Number |
83-1057067
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 15507 furlong circle, Odessa, FL, 33556, UN |
Mail Address: | 15507 furlong circle, Odessa, FL, 33556, UN |
ZIP code: | 33556 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
aguiar miguel | Authorized Member | 15507 furlong circle, odessa, fl, 33556 |
Aguiar Olga | Manager | 15507 furlong circle, Odessa, fl, 33556 |
Aguiar Miguel | Agent | 15507 furlong circle, Odessa, FL, 33556 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2024-09-27 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2022-03-05 | 15507 furlong circle, Odessa, FL 33556 UN | - |
REGISTERED AGENT NAME CHANGED | 2022-03-05 | Aguiar, Miguel | - |
REGISTERED AGENT ADDRESS CHANGED | 2022-03-05 | 15507 furlong circle, Odessa, FL 33556 | - |
CHANGE OF MAILING ADDRESS | 2022-03-05 | 15507 furlong circle, Odessa, FL 33556 UN | - |
LC AMENDMENT | 2019-08-15 | - | - |
LC AMENDMENT | 2019-07-05 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2023-04-02 |
ANNUAL REPORT | 2022-03-05 |
ANNUAL REPORT | 2021-04-09 |
ANNUAL REPORT | 2020-01-06 |
LC Amendment | 2019-08-15 |
LC Amendment | 2019-07-05 |
ANNUAL REPORT | 2019-01-29 |
ANNUAL REPORT | 2018-06-28 |
Florida Limited Liability | 2017-11-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343763413 | 0420600 | 2019-02-05 | 7924 PELICAN REED CIRCLE, WESLEY CHAPEL, FL, 33543 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1376014 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-02-21 |
Emphasis | L: FALL |
Case Closed | 2019-03-22 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2018-06-04 |
Current Penalty | 1884.5 |
Initial Penalty | 3769.0 |
Contest Date | 2018-07-23 |
Final Order | 2019-02-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a) At the site - the scaffold was not fully planked, exposing the employees to a fall hazard, on or about 2/21/2018. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2018-06-04 |
Current Penalty | 1256.5 |
Initial Penalty | 2513.0 |
Contest Date | 2018-07-23 |
Final Order | 2019-02-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) At the site - a ladder was not provided for access/egress to the tubular welded frame scaffold system, on or about 2/21/2018. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2018-06-04 |
Current Penalty | 2217.0 |
Initial Penalty | 4434.0 |
Contest Date | 2018-07-23 |
Final Order | 2019-02-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) At the site - employees were exposed to a 12'5" fall hazard while working from the tubular welded frame scaffold that was not protected by guardrails, on or about 02/21/2018. |