Search icon

MONDRAGON CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: MONDRAGON CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

MONDRAGON CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 29 Mar 2017 (8 years ago)
Date of dissolution: 06 Apr 2022 (3 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 06 Apr 2022 (3 years ago)
Document Number: L17000071330
FEI/EIN Number 82-1071184

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5075 countryside court, St cloud, FL, 34771, US
Mail Address: 5075 countryside court, St cloud, FL, 34771, US
ZIP code: 34771
County: Osceola
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Mondragon Saul Owne 5075 countryside court, St cloud, FL, 34771
Mondragon Saul Agent 5075 countryside court, St cloud, FL, 34771

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2022-04-06 - -
CHANGE OF PRINCIPAL ADDRESS 2021-12-10 5075 countryside court, St cloud, FL 34771 -
REGISTERED AGENT NAME CHANGED 2021-12-10 Mondragon , Saul -
REGISTERED AGENT ADDRESS CHANGED 2021-12-10 5075 countryside court, St cloud, FL 34771 -
CHANGE OF MAILING ADDRESS 2021-12-10 5075 countryside court, St cloud, FL 34771 -
REINSTATEMENT 2018-10-17 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2022-04-06
AMENDED ANNUAL REPORT 2021-12-10
ANNUAL REPORT 2021-01-08
ANNUAL REPORT 2020-01-13
ANNUAL REPORT 2019-01-04
REINSTATEMENT 2018-10-17
Florida Limited Liability 2017-03-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343817805 0420600 2019-02-27 2005 HARBOR WATCH CIRCLE, TARPON SPRINGS, FL, 34690
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2019-02-27
Emphasis L: FALL
Case Closed 2022-06-17

Related Activity

Type Complaint
Activity Nr 1430067
Safety Yes
Type Inspection
Activity Nr 1381775
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-06-27
Current Penalty 1705.0
Initial Penalty 3410.0
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): a) Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On or about 2/27/2019, at the jobsite, employees operating nail guns were exposed to a struck-by hazard, in that, eye protection was not used.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2019-06-27
Current Penalty 1989.0
Initial Penalty 3978.0
Final Order 2019-08-12
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a. On or about 2/25/2019, at the jobsite, the floor openings near the interior staircase were not protected, exposing employees to a 6 foot fall hazard. b. On or about 2/27/2019, at the jobsite, the floor openings near the interior staircase were not protected, exposing employees to a 6 foot fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-06-27
Abatement Due Date 2019-07-10
Current Penalty 1989.0
Initial Penalty 3978.0
Final Order 2019-08-12
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 2/25/2019, at the jobsite, employees installing wood roof trusses on a new construction residential property were not protected from falling 35 feet to the ground below. b. On or about 2/27/2019, at the jobsite, employees installing fascia boards on a new construction residential property were not protected from falling 35 feet to the ground below.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2019-06-27
Abatement Due Date 2019-07-10
Current Penalty 1989.0
Initial Penalty 3978.0
Final Order 2019-08-12
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a. On or about 2/25/2019, at the jobsite, the interior staircase used by employees did not have hand rails and employees were exposed to a 6-12 foot fall. b. On or about 2/27/2019, at the jobsite, the interior staircase used by employees did not have hand rails and employees were exposed to a 6-12 foot fall.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2019-06-27
Abatement Due Date 2019-07-10
Current Penalty 1989.0
Initial Penalty 3978.0
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about 2/27/2019, at the jobsite, employees used the top step of an 8 foot step ladder to install fascia boards and to gain access to the roof trusses, exposing employees to a fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A02
Issuance Date 2019-06-27
Abatement Due Date 2019-07-10
Current Penalty 159.5
Initial Penalty 319.0
Final Order 2019-08-12
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a. On or about 2/25/2019, at the jobsite, untrained employees were directed to install wood roof trusses work without being informed how to recognize and handle hazards associated with working at heights and the proper selection and use of fall protection. b. On or about 2/27/2019, at the jobsite, untrained employees were directed to work on a 6/12 pitch roof without being informed how to recognize and handle hazards associated with working at heights and the proper selection and use of fall protection.
Citation ID 02002
Citaton Type Other
Standard Cited 19261060 A01
Issuance Date 2019-06-27
Abatement Due Date 2019-07-24
Current Penalty 159.5
Initial Penalty 319.0
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards: a. On or about 2/27/2019, at the jobsite, employees who utilized ladders to install fascia and gain access to the roof trusses were not provided with training on ladder use and the hazards associated with using ladders.

Date of last update: 01 Apr 2025

Sources: Florida Department of State