Search icon

1ST CHOICE HURRICANE PROTECTION LLC - Florida Company Profile

Company Details

Entity Name: 1ST CHOICE HURRICANE PROTECTION LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

1ST CHOICE HURRICANE PROTECTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 15 Mar 2017 (8 years ago)
Document Number: L17000060020
FEI/EIN Number 820842158

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 25241 BERNWOOD DR, SUITE 6, BONITA SPRINGS, FL, 34135, UN
Mail Address: 25241 BERNWOOD DR, SUITE 6, BONITA SPRINGS, FL, 34135, UN
ZIP code: 34135
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LUSTIK LANCE W Manager 25241 BERNWOOD DR. SUITE 6, BONITA SPRINGS, FL, 34135
EVANS LAUREN A Authorized Member 25241 BERNWOOD DR. STE 6, BONITA SPRINGS, FL, 34135
LUSTIK LANCE W Agent 25241 BERNWOOD DR., BONITA SPRINGS, FL, 34135

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G24000006088 1ST CHOICE OUTDOORS ACTIVE 2024-01-10 2029-12-31 - 25241 BERNWOOD DR., STE. 4, BONITA SPRINGS, FL, 34135
G17000037176 1ST CHOICE WINDOWS AND DOORS ACTIVE 2017-04-06 2027-12-31 - 25241 BERNWOOD DRIVE, SUITE 6, BONITA SPRINGS, FL, 34135

Documents

Name Date
ANNUAL REPORT 2024-04-05
ANNUAL REPORT 2023-04-03
ANNUAL REPORT 2022-02-23
ANNUAL REPORT 2021-01-31
ANNUAL REPORT 2020-01-14
ANNUAL REPORT 2019-02-08
ANNUAL REPORT 2018-01-15
Florida Limited Liability 2017-03-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346014038 0420600 2022-06-14 27086 SHELL RIDGE CIRCLE, BONITA SPRINGS, FL, 34133
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-06-14
Emphasis L: FALL
Case Closed 2023-08-29

Related Activity

Type Referral
Activity Nr 1903107
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2022-07-15
Abatement Due Date 2022-08-10
Current Penalty 5075.5
Initial Penalty 10151.0
Final Order 2022-08-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide: a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the working level of the scaffold was not fully planked or decked such that the space between adjacent units, and the space between the platform and the uprights was more than 1 inch wide; therefore exposing the employees to a 14'-9" fall hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2022-07-15
Abatement Due Date 2022-08-10
Current Penalty 5075.5
Initial Penalty 10151.0
Final Order 2022-08-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the scaffold and scaffold components had not been erected, moved, dismantled and altered by trained and experienced employees, nor while under the supervision and direction of a scaffolding competent person nor while under the supervision and direction of a scaffolding qualified person, and wherein the scaffold system was found to contain several visible predictable hazards such as having not been fully planked and having been missing the guardrails; therefore exposing the employees to a 14'-9" fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2022-07-15
Abatement Due Date 2022-08-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the scaffold and scaffold components had not been inspected by a competent person prior to use, and wherein the scaffold system was found to contain several visible predictable hazards such as having not been fully planked and having been missing the guardrails; therefore exposing the employees to a 14'-9" fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2022-07-15
Abatement Due Date 2022-08-10
Current Penalty 5075.5
Initial Penalty 10151.0
Final Order 2022-08-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about June 08, 2022, employees were installing windows on a two-story single-family home from a 2-tier supported scaffold, during which time the employees were not using a Personal Fall Arrest System nor was the three open sides of the working level of the scaffold protected with a guardrail system; therefore exposing the employees to a 14'-9" fall hazard.