Search icon

CARLOS MARADIAGA LLC - Florida Company Profile

Company Details

Entity Name: CARLOS MARADIAGA LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CARLOS MARADIAGA LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 14 Nov 2016 (8 years ago)
Document Number: L16000207632
FEI/EIN Number 81-4421791

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7209 MAPLE TREE DR, JACKSONVILLE, FL, 32277, US
Mail Address: 7209 MAPLE TREE DR, JACKSONVILLE, FL, 32277, US
ZIP code: 32277
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MARADIAGA-GARCIA CARLOS Manager 7209 MAPLE TREE DR, JACKSONVILLE, FL, 32277
MARADIAGA-GARCIA CARLOS Agent 7209 MAPLE TREE DR, JACKSONVILLE, FL, 32277

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G20000053025 CARLOS MARADIAGA SIDING ACTIVE 2020-05-13 2025-12-31 - 2204 NATHAN WEST DR, JACKSONVILLE, FL, 32216

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2022-11-21 7209 MAPLE TREE DR, JACKSONVILLE, FL 32277 -
CHANGE OF MAILING ADDRESS 2022-11-21 7209 MAPLE TREE DR, JACKSONVILLE, FL 32277 -
REGISTERED AGENT ADDRESS CHANGED 2022-11-21 7209 MAPLE TREE DR, JACKSONVILLE, FL 32277 -

Documents

Name Date
ANNUAL REPORT 2024-04-29
ANNUAL REPORT 2023-04-03
AMENDED ANNUAL REPORT 2022-11-21
ANNUAL REPORT 2022-04-11
ANNUAL REPORT 2021-03-29
ANNUAL REPORT 2020-03-09
ANNUAL REPORT 2019-04-25
ANNUAL REPORT 2018-04-25
ANNUAL REPORT 2017-05-01
Florida Limited Liability 2016-11-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346792237 0419700 2023-06-26 75427 FOX CROSS AVENUE LOT 553, YULEE, FL, 32041
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-07-06
Emphasis L: FALL, P: FALL
Case Closed 2024-02-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-08-09
Abatement Due Date 2023-08-21
Current Penalty 2812.8
Initial Penalty 4688.0
Final Order 2023-09-20
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the front elevation of home, on a 5:12 pitched roof of a temporary residential job site, located at 75427 Fox Cross Avenue - Lot 553, Yulee, Florida 32041: On or about June 26, 2023, the employer exposed an employee to fall hazards ranging from 9 to 29 feet, in that fall protection was not utilized by the employee while installing exterior soffit and siding materials.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2023-08-09
Current Penalty 2410.8
Initial Penalty 4018.0
Final Order 2023-09-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed: a. On the roof of a temporary residential worksite, located at 75427 Fox Cross Avenue - Lot 553, Yulee, FL 32041: On or about June 26, 2023, the employer exposed an employee to fall hazards, in that an employee was using an A-frame type potable ladder in the closed position and leaned against the residence to install exterior soffit and siding materials.
Citation ID 02001
Citaton Type Other
Standard Cited 19260102 B01 I
Issuance Date 2023-08-09
Abatement Due Date 2023-08-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-20
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(b)(1)(i): Protective eye and face protection devices did not comply with consensus standard; ANSI/ISEA Z87.1-2010, Occupational and Educational Personal Eye and Face Protection Devices, incorporated by reference in � 1926.6: a. At a temporary residential job site, located at 75427 Fox Cross Avenue - Lot 553, Yulee, FL 32041: On or about June 26, 2023, the employer exposed an employee to eye injury hazards caused by airborne debris and flying objects, in that the employee was permitted to operate a pneumatic nail gun supplied with air pressure while wearing sunglasses to install exterior soffit and siding materials.