Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-02-09
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-28
|
Related Activity
Type |
Referral |
Activity Nr |
1307898 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260095 B |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(b): Where employees provide their own protective equipment, the employer did not assure its adequacy, including proper maintenance, and sanitation of such equipment: On or about 02/08/2018, at 245 30 street, Miami Beach, FL 33140, the employer did not inspect employee owned equipment when it was used everyday exposing the employee to a fall hazard. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260095 D01 |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(d)(1): Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employee(s): On or about 02/09/2018, at 245 30 street, Miami Beach, FL 33140, the employer did not pay for the safety equipment that the employees were required to use. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
9054.0 |
Initial Penalty |
9054.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 02/09/2018, at 245 30 street, Miami Beach, FL 33140, a working platform in an elevator shaft had not been inspected for damage resulting in an employee injury from a fall. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: On or about 02/08/2018, at 245 30 street, Miami Beach, FL 33140, employees were exposed to a fall of approximately 10-feet while working near an elevator shaft that did not have a guardrail. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
9054.0 |
Initial Penalty |
9054.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about 02/09/2018, at 245 30 street, Miami Beach, FL 33140, the above addressed worksite, the employer failed to provide fall protection along the unprotected edge of the second floor exposing employees to fall hazards of up to approximately 10-feet. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-17 |
Current Penalty |
6467.0 |
Initial Penalty |
6467.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): On or about 02/09/2018, at 245 30 street, Miami Beach, FL 33140, the employer did not ensure that employees using personal fall protection harnesses had been trained in the use of the equipment. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2018-08-07 |
Abatement Due Date |
2018-08-13 |
Current Penalty |
9054.0 |
Initial Penalty |
9054.0 |
Final Order |
2018-09-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: On or about 02/08/2018, at 245 30 street, Miami Beach, FL 33140, the employer did not provide handrails on stairways in a hallway exposing employees to a fall of up to 10-feet. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 D01 |
Issuance Date |
2019-01-15 |
Abatement Due Date |
2019-01-28 |
Current Penalty |
0.0 |
Initial Penalty |
726.0 |
Final Order |
2019-02-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: On or about 09/04/2018, the employer failed to submit documentation and certification of corrective action for: Citation 01, Item 01a, issued on 08/07/2018 with an abatement due date of 09/04/2018. Citation 01, Item 02a, issued on 08/07/2018 with an abatement due date of 09/04/2018. Citation 01, Item 02b, issued on 08/07/2018 with an abatement due date of 09/04/2018. Citation 01, Item 03, issued on 08/07/2018 with an abatement due date of 09/04/2018. Citation 01, Item 05, issued on 08/07/2018 with an abatement due date of 09/04/2018. |
|
|