Entity Name: | BDT ROOFING OF FLORIDA LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
BDT ROOFING OF FLORIDA LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 25 Apr 2016 (9 years ago) |
Date of dissolution: | 24 Sep 2021 (4 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 24 Sep 2021 (4 years ago) |
Document Number: | L16000081111 |
FEI/EIN Number |
81-2433684
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 7040 SEMINOLE PRATT WHITNEY ROAD,, LOXAHATCHEE, FL, 33470, US |
Mail Address: | 7040 Seminole Pratt Whitney Road Suite 25, Loxahatchee, FL, 33470, US |
ZIP code: | 33470 |
County: | Palm Beach |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Marinacci Donald R | Manager | 7040 Seminole Pratt Whitney Road Suite 25, Loxahatchee, FL, 33470 |
MARINACCI DONALD R | Authorized Member | 1705 DONNA RD. UNIT 16, WEST PALM BEACH, FL, 33409 |
Marinacci Donald R | Agent | 7040 Seminole Pratt Whitney Road, Loxahatchee, FL, 33470 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2021-09-24 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2020-01-14 | 7040 Seminole Pratt Whitney Road, Suite 25 #175, Loxahatchee, FL 33470 | - |
REGISTERED AGENT NAME CHANGED | 2020-01-14 | Marinacci, Donald R | - |
CHANGE OF MAILING ADDRESS | 2018-01-17 | 7040 SEMINOLE PRATT WHITNEY ROAD,, SUITE 25 #175, LOXAHATCHEE, FL 33470 | - |
CHANGE OF PRINCIPAL ADDRESS | 2017-11-27 | 7040 SEMINOLE PRATT WHITNEY ROAD,, SUITE 25 #175, LOXAHATCHEE, FL 33470 | - |
REINSTATEMENT | 2017-09-29 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J21000275366 | ACTIVE | 20-3599-CI | PINELLAS CIRCUIT CIVIL | 2021-05-20 | 2026-06-08 | $44,118.73 | BEACON SALES ACQUISITION, INC., 8501 SABAL INDUSTRIAL BLVD, TAMPA, FL 33619 |
J17000457988 | LAPSED | 50 2017 CC 005825 XXXX MB | PALM BEACH CO. | 2017-08-03 | 2022-08-14 | $6970.51 | CINTAS CORPORATION NO. 2 DBA, CONTAS CORPORATION, 2401 VISTA PARKWAY, WEST PALM BEACH, FLORIDA 33411 |
Name | Date |
---|---|
ANNUAL REPORT | 2020-01-14 |
ANNUAL REPORT | 2019-01-11 |
ANNUAL REPORT | 2018-01-17 |
REINSTATEMENT | 2017-09-29 |
Florida Limited Liability | 2016-04-25 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344384169 | 0418800 | 2019-10-17 | 400 BINKS FOREST DRIVE, WELLINGTON, FL, 33414 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1509647 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1439259 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1438440 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2020-03-20 |
Abatement Due Date | 2020-04-08 |
Current Penalty | 3856.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-04-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: On or about October 17, 2019, on the roof leading to a porte cochère of a country club clubhouse under renovation located at 400 Binks Forest Drive in Wellington, Florida, an employee was exposed to fall hazard of approximately 16 feet - 6 inches when performing aluminum flashing installation work from a roof with a 5:12 pitch while not being protected from falling to a lower level. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2020-03-20 |
Abatement Due Date | 2020-04-08 |
Current Penalty | 3856.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-04-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: On or about October 17, 2019, at the northwest exterior entrance of a country club clubhouse under renovation located at 400 Binks Forest Drive in Wellington, Florida, an employee preparing to perform aluminum flashing installation work was exposed to a fall of approximately 12 feet when climbing a ladder while carrying a section of flashing in his left hand. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2019-09-09 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2022-04-05 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2020-01-30 |
Abatement Due Date | 2020-03-06 |
Current Penalty | 2698.5 |
Initial Penalty | 5397.0 |
Final Order | 2020-02-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels are not protected by guardrail systems, safety net system, or personal fall arrest system, nor provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about September 9, 2019, employees performing roofing work were not protected from fall hazards greater than 15-feet to the ground below on a job site located at, 2668 Greenway Road, Jupiter FL. |