Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-10-31
|
Case Closed |
2019-04-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1364042 |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
1396355 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 G06 |
Issuance Date |
2019-01-23 |
Abatement Due Date |
2019-03-25 |
Current Penalty |
5115.0 |
Initial Penalty |
8525.0 |
Final Order |
2019-02-13 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : a. On or about November 6, 2018, at 7860 NW 66th St. Miami, FL 33166 bindery department, an employee operating a folding machine was exposed to a noise level of 87.2 dBA, which exceeds the 85.0 dBA during the 8-hr representative sampling period. The employer failed to provide the employee with an annual audiogram after the employees' first baseline. b. On or about November 6, 2018, at 7860 NW 66th St. Miami, FL 33166 press department, an employee operating as a second press operator was exposed to a noise level of 90.7 dBA, which exceeds the 85.0 dBA during the 8-hr representative sampling period. The employer failed to provide the employee with an annual audiogram after the employees' first baseline. c. On or about November 6, 2018, at 7860 NW 66th St. Miami, FL 33166 bindery department, an employee operating a die-cutter machine was exposed to a noise level of 91.0 dBA, which exceeds the 85.0 dBA during the 8-hr representative sampling period. The employer failed to provide the employee with an annual audiogram after the employees' first baseline. d. On or about November 6, 2018, at 7860 NW 66th St. Miami, FL 33166 baler department, an employee operating a baler machine was exposed to a noise level of 93.3 dBA, which exceeds the 85.0 dBA during the 8-hr representative sampling period. The employer failed to provide the employee with an annual audiogram after the employees' first baseline. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 I05 |
Issuance Date |
2019-01-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors: On or about October 31, 2018, at 7860 NW 66th St. Miami, FL 33166 bindery department, an employee assisting the folding machine operator was exposed to a noise level of 87.2 dBA, which exceeds the action level of 85.0 dBA, during the 8-hr representative sampling period. The employer failed to ensure the assistant working alongside this employee was wearing hearing protection properly. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2019-01-23 |
Abatement Due Date |
2019-03-25 |
Current Penalty |
4091.4 |
Initial Penalty |
6819.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: On or about 10/31/2018, at the jobsite location 7860 NW 66th St. Miami, FL 3166 pre-press department, employees who were exposed to an eye injury while handling chemicals such as but not limited to LP-D3W, were not protected while not wearing any eye protection. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 II |
Issuance Date |
2019-01-23 |
Current Penalty |
3069.0 |
Initial Penalty |
5115.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: On or about 10/31/2018, at the jobsite location 7860 NW 66th St. Miami, FL 33166 in the press department, the SES 2750PX -AS2 silicon 55 gallon drum was not labeled with the required information. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2019-01-23 |
Abatement Due Date |
2019-03-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about 10/31/2018 at , FL 33172, the employer did not provide employees, who voluntarily use a filtering-facepiece respirator with a copy of the information contained in Appendix D of 29 CFR 1910.134. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2019-01-23 |
Abatement Due Date |
2019-03-25 |
Current Penalty |
574.2 |
Initial Penalty |
957.0 |
Final Order |
2019-02-13 |
Nr Instances |
2 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 10/31/2018 at 7860 NW 66th St. Miami, FL 33166 pre-press department, employees would use a corrosive chemical known as LP-D3W Plate Replenisher (with a pH 12.1), without having an eye wash station readily available. b) On or about 10/31/2018 at 7860 NW 66th St. Miami, FL 33166 press department, employees would use a corrosive chemical known as Relief (with a pH 2.2-2.4), without having an eye wash station readily available. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-06
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2019-04-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1352632 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100029 B02 |
Issuance Date |
2019-01-23 |
Current Penalty |
3477.6 |
Initial Penalty |
5796.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.29(b)(2): The employer did not ensure that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high: On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 67th St, Miami FL. An employee was exposed to a fall hazard while working in a work platform whose guardrail system lacked a midrail, exposing employee to a fall hazard of 8'-4" to floor level. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2019-01-23 |
Current Penalty |
3477.6 |
Initial Penalty |
5796.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 66th St, Miami FL. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Wilton, 8-inch) that lacked a tongue guard on its left side. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2019-01-23 |
Current Penalty |
2956.2 |
Initial Penalty |
4927.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 66th St, Miami FL. A carton sealer (i.e. Interpack) lacked a ground prong on its attachment plug, exposing an employee to an electrical shock hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2019-01-23 |
Abatement Due Date |
2019-03-25 |
Current Penalty |
870.0 |
Initial Penalty |
1450.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
120 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent: On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 66th St, Miami FL. The employer had not recorded injuries and/or illnesses for 2018 in an OSHA-300 form. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100037 B05 |
Issuance Date |
2019-01-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 66th St, Miami FL. A Pre-press department door leading to the exterior which was maintained locked and could easily be mistaken as an exit, was not marked as "Not an exit", exposing employees to the risk of being trapped in the event of a fire. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2019-01-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about October 11, 2018, at the Solo Printing LLC Building located at 7860 NW 66th St, Miami FL. A strapping machine (i.e. Stra Pack JK-2) lacked of strain relief where its cable entered into the attachment, exposing an employee to an electrical shock hazard. |
|
|