Entity Name: | DAVE'S HOMEWORK OF PINELLAS LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
DAVE'S HOMEWORK OF PINELLAS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 27 Jan 2016 (9 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 03 Oct 2023 (2 years ago) |
Document Number: | L16000018903 |
FEI/EIN Number |
81-1314067
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1801 63RD TER S, ST.PETERSBURG, FL, 33712 |
Mail Address: | 1801 63RD TER S, ST.PETERSBURG, FL, 33712 |
ZIP code: | 33712 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
MIDDLETON DAVID | Manager | 1801 63RD TER S, ST.PETERSBURG, FL, 33712 |
MIDDLETON DAVID | Agent | 1801 63RD TER S, ST.PETERSBURG, FL, 33712 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2023-10-03 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2023-09-22 | - | - |
REINSTATEMENT | 2019-01-09 | - | - |
REGISTERED AGENT NAME CHANGED | 2019-01-09 | MIDDLETON, DAVID | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2018-09-28 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-24 |
REINSTATEMENT | 2023-10-03 |
ANNUAL REPORT | 2022-04-06 |
ANNUAL REPORT | 2021-01-15 |
ANNUAL REPORT | 2020-08-15 |
REINSTATEMENT | 2019-01-09 |
ANNUAL REPORT | 2017-04-28 |
Florida Limited Liability | 2016-01-27 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344108451 | 0420600 | 2019-06-25 | 48 COLUMBIA DR, TAMPA, FL, 33606 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1469098 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 C02 |
Issuance Date | 2019-09-30 |
Current Penalty | 3978.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-10-25 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) For employees doing masonry work at 48 Columbia Drive in Tampa, on or about 25 June, 2019. The tubular frame scaffold used by employees had the uprights placed directly on the wood subfloor without the use of base plates creating a fall hazard. Employees exposed to an approximate 11 feet 9 inch fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2019-09-30 |
Abatement Due Date | 2019-10-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-10-25 |
Nr Instances | 7 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) For employees doing masonry work at 48 Columbia Drive in Tampa, on or about 25 June, 2019. Employees were not trained on the hazards of scaffolding and how to assemble the scaffold correctly. Employees designated as competent erected tubular frame scaffolding without the use of base plates creating a scaffold collapse fall hazard. |
Date of last update: 01 Apr 2025
Sources: Florida Department of State