343457321
|
0420600
|
2018-09-11
|
4690 TIVOLI DRIVE, WESLEY CHAPEL, FL, 33543
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-09-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2018-09-25 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-11-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) 4690 Tivoli Drive - employees in the process of plastering stucco were exposed to fall hazards up to 14 feet, in that, work platforms on the 2nd level of the scaffolding system were not fully planked or decked. Observed on or about 9/11/2018. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2018-09-25 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-11-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: b) 4690 Tivoli Drive - the base of the tubular welded frame scaffolding was not adequately supported, in that, mudsills were not installed on the scaffold legs to provide a firm foundation. Observed on or about 9/11/2018. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2018-09-25 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-11-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. b) 4690 Tivoli Drive - employees were exposed to fall hazards up to 14 feet while climbing up and down the end section of a walk through style tubular welded frame scaffold. An access ladder was not installed. Observed on or about 9/11/2018. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2018-09-25 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-11-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) 4690 Tivoli Drive - employees in the process of plastering stucco were exposed to a 14 foot fall hazard, in that, a guard rail was not installed, southwest corner, top work platform of the scaffolding system. Observed on or about 9/11/2018. |
|
|
343216073
|
0420600
|
2018-06-08
|
TRINITY BLVD & EPIPHANY WAY BUILDING J, TRINITY, FL, 34655
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-02
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2018-12-03 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2019-01-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) on the jobsite, south east corner - the portable extension ladder that was extended from the ground up to the 3rd buck did not provide access to the platform of the 4th buck, exposing employees to a 13ft,9.5in up to 20ft,3in fall hazard; observed on or about 6/8/2018. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2018-12-03 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface and the ladder's length allowed, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) on the jobsite, south east corner - the portable extension ladder did not extend 3 feet above the platform of the 3rd buck of the tubular welded frame scaffold, exposing employees to a 13ft,9.5in fall hazard; observed on or about 6/8/2018. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2018-12-03 |
Abatement Due Date |
2018-12-28 |
Current Penalty |
2772.0 |
Initial Penalty |
2772.0 |
Final Order |
2019-01-03 |
Nr Instances |
6 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of scaffold platforms: (a) eastern side of building - missing end guardrail at the north end of the 4th buck, exposing employees to a 20ft,3in fall hazard; observed on or about 6/8/2018. (b) eastern side of building - missing mid-rail at the southern section of the 4th buck, exposing employees to a 20ft,3in fall hazard; observed on or about 6/8/2018. (c) eastern side of building - missing guardrails at the southern section of the 3rd buck where the top of the access ladder was located, exposing employees to a 13ft,9.5in fall hazard; observed on or about 6/8/2018. (d) eastern side of building - missing mid-rails at the middle section and northern section of the 3rd buck, exposing employees to a 13ft,9.5in fall hazard; observed on or about 6/8/2018. (e) eastern side of building - missing end guardrail at the north end of the 3rd buck, exposing employees to a 13ft,9.5in fall hazard; observed on or about 6/8/2018. (f) southern side of building - missing mid-rail at the middle section of the 3rd buck, exposing employees to a 13ft,9.5in fall hazard; observed on or about 6/8/2018. |
|
|
342964491
|
0420600
|
2018-02-21
|
8295 OLIVE BROOK DR., WESLEY CHAPEL, FL, 33543
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-02-21
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-03-07 |
Current Penalty |
3492.0 |
Initial Penalty |
3492.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 8295 Olive Brook Dr.- An employee in the process of decking the 6 in 12 slope (vertical to horizontal) roof, were exposed to fall hazards up to a 9'4" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 02/21/2018. |
|
|