Entity Name: | SUPERIOR ROOFING & REPAIR SERVICES, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
SUPERIOR ROOFING & REPAIR SERVICES, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 15 Dec 2015 (9 years ago) |
Document Number: | L15000208354 |
FEI/EIN Number |
30-0992926
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL, 34953 |
Mail Address: | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL, 34953 |
ZIP code: | 34953 |
County: | St. Lucie |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RENTERIA JOSE | Authorized Member | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL, 34953 |
RENTERIA MIKE | Authorized Member | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL, 34953 |
RENTERIA JOSE | Agent | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL, 34953 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G24000048430 | SUPERIOR ROOFING & REPAIR SERVICES LLC | ACTIVE | 2024-04-10 | 2029-12-31 | - | 1081 SW INGRASSINA AVE., PORT SAINT LUCIE, FL, 34953 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2018-04-13 | RENTERIA, JOSE | - |
REGISTERED AGENT ADDRESS CHANGED | 2018-04-13 | 1081 S.W. INGRASSINA AVE., PORT ST. LUCIE, FL 34953 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-12 |
ANNUAL REPORT | 2024-01-25 |
ANNUAL REPORT | 2023-02-15 |
ANNUAL REPORT | 2022-01-12 |
ANNUAL REPORT | 2021-01-31 |
ANNUAL REPORT | 2020-02-11 |
ANNUAL REPORT | 2019-03-13 |
ANNUAL REPORT | 2018-04-13 |
ANNUAL REPORT | 2017-03-02 |
ANNUAL REPORT | 2016-03-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345704084 | 0418800 | 2021-12-27 | 165 SW FAIRVIEW AVE, PORT SAINT LUCIE, FL, 34983 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Repeat |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-01-27 |
Current Penalty | 7459.0 |
Initial Penalty | 7459.0 |
Final Order | 2022-02-23 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about December 27, 2021, at 165 Fairview Ave, Port Saint Lucie, FL, 34983; employees were exposed to a fall hazard of approximately a 8 feet while performing roof demolition work without using any conventional fall protection system on a roof of a residence with a 4:12 pitch. The SUPERIOR ROOFING & REPAIR SERVICES, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1356266, citation number 1, item number 1 and was affirmed as a final order on 2/20/2019, with respect to a workplace located at 1081 Ingrassina Ave, Port Saint Lucie, FL, 34952. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-10-24 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2019-03-07 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-11-13 |
Abatement Due Date | 2018-12-03 |
Current Penalty | 3326.0 |
Initial Penalty | 3326.0 |
Final Order | 2018-12-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about October 24, 2018, at 1081 Ingrassina Ave, Port Saint Lucie, FL, 34952; employees were exposed to a fall hazard of approximately a 9 feet while installing shingles work without using any conventional fall protection system on a roof of a residence with a 5:12 pitch. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19030019 C01 |
Issuance Date | 2019-01-17 |
Abatement Due Date | 2019-03-07 |
Current Penalty | 311.0 |
Initial Penalty | 311.0 |
Final Order | 2019-02-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a. On or about 09/07/2018, the employer failed to submit certification of corrective action for citation 1, item 1, citation 1, item 2, citation 1, item 3, citation 1, item 4, citation 1, item 5, citation 1, item 6, citation 1, item 7 issued on 05/29/2018 with an abatement due date of 06/09/2018. |
Date of last update: 02 Mar 2025
Sources: Florida Department of State