Entity Name: | CONSERVE LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
CONSERVE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 08 Oct 2015 (10 years ago) |
Document Number: | L15000171799 |
FEI/EIN Number |
47-5276284
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5060 PARETE RD S, JACKSONVILLE, FL, 32218 |
Mail Address: | 5060 PARETE RD S, JACKSONVILLE, FL, 32218 |
ZIP code: | 32218 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
KIMES CHESTER F | Manager | 5060 PARETE RD S, JACKSONVILLE, FL, 32218 |
JEFFERSON JOE D | Agent | 5412 MORSE AVE, JACKSONVILLE, FL, 32244 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2020-05-05 | JEFFERSON, JOE D | - |
REGISTERED AGENT ADDRESS CHANGED | 2020-05-05 | 5412 MORSE AVE, JACKSONVILLE, FL 32244 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-09 |
ANNUAL REPORT | 2024-02-04 |
ANNUAL REPORT | 2023-04-06 |
ANNUAL REPORT | 2022-04-24 |
ANNUAL REPORT | 2021-04-19 |
ANNUAL REPORT | 2020-05-05 |
ANNUAL REPORT | 2019-04-05 |
ANNUAL REPORT | 2018-04-11 |
ANNUAL REPORT | 2017-04-30 |
ANNUAL REPORT | 2016-05-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341917656 | 0419700 | 2016-11-17 | 1651 MAYPORT RD, MAYPORT, FL, 32233 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2016-11-29 |
Current Penalty | 0.0 |
Initial Penalty | 3741.0 |
Final Order | 2016-12-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On November 17, 2016, on the balcony, employees performing framing and decking work were not protected from a 15 feet fall hazard by the use of a fall protection system. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2016-11-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-12-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On November 17, 2016, on the east side of the building, the ladder used to access and egress the balcony did not extend 3 feet above the landing, exposing employees to a 15 feet hazard. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State