Search icon

TRIDENT CONSTRUCTION OF FLORIDA LLC

Company Details

Entity Name: TRIDENT CONSTRUCTION OF FLORIDA LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Inactive
Date Filed: 24 Jun 2015 (10 years ago)
Date of dissolution: 22 Sep 2017 (7 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (7 years ago)
Document Number: L15000109396
FEI/EIN Number 47-4388441
Address: 2400 SW 42ND AVE., FORT LAUDERDALE, FL 33317
Mail Address: 2400 SW 42ND AVE., FORT LAUDERDALE, FL 33317
ZIP code: 33317
County: Broward
Place of Formation: FLORIDA

Agent

Name Role Address
MEJIA, LUIS F Agent 4230 SW 24TH STREET, FORT LAUDERDALE, FL 33317

Manager

Name Role Address
MEJIA, LUIS F Manager 4230 SW 24TH STREET, FORT LAUDERDALE, FL 33317

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 No data No data
LC AMENDMENT 2016-12-02 No data No data
REGISTERED AGENT NAME CHANGED 2016-12-02 MEJIA, LUIS F No data
CHANGE OF PRINCIPAL ADDRESS 2016-08-23 2400 SW 42ND AVE., FORT LAUDERDALE, FL 33317 No data
CHANGE OF MAILING ADDRESS 2016-08-23 2400 SW 42ND AVE., FORT LAUDERDALE, FL 33317 No data
LC AMENDMENT 2015-11-23 No data No data
LC AMENDMENT 2015-10-30 No data No data

Documents

Name Date
LC Amendment 2016-12-02
AMENDED ANNUAL REPORT 2016-05-18
ANNUAL REPORT 2016-04-30
LC Amendment 2015-11-23
LC Amendment 2015-10-30
Florida Limited Liability 2015-06-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341505204 0418800 2016-05-26 1921 NW FEDERAL HIGHWAY, JENSEN BEACH, FL, 34957
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-05-26
Emphasis P: FALL, L: FALL
Case Closed 2019-12-02

Related Activity

Type Inspection
Activity Nr 1150555
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about May 26, 2016, at the above addressed site, an employee was exposed to a fall hazard of approximately 19 feet when performing form removal work from the work level platform of a fabricated frame scaffold that was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about May 26, 2016, at the above addressed site, employees were exposed to a fall hazard of approximately 25 feet when performing form removal work from the a fabricated frame scaffold that did not have the frame legs bearing on baseplates and/or mudsills.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: On or about May 26, 2016, at the above addressed site, an employee was exposed to a fall hazard of approximately 25 feet 4 inches when descending a fabricated frame scaffold that was not provided with a ladder, stairway or ramp for a safe means of access.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F15 I
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(15)(i): A ladder placed against a structure which was not part of the scaffold was not secured against the sideways thrust exerted by the ladder: On or about May 26, 2016, at the above addressed site, an employee was exposed to a fall hazard of approximately 25 feet 4 inches when performing form removal work from a ladder placed on the work level platform of a fabricated frame scaffold and against a structure while that scaffold was not secured to prevent sideways thrust exerted by the ladder.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about May 26, 2016, at the above addressed site, employees were exposed to a fall hazards of approximately 25 feet 4 inches and 19 feet when performing form removal work from the work level platforms of a fabricated frame scaffold while not being protected from falling.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2016-06-29
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about May 26, 2016, at the above addressed site, employees were exposed to fall hazards of approximately 25 feet 4 inches and 19 feet when performing form removal work from a fabricated frame scaffold that was not inspected for visible defects by a competent person before the work shift.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2016-06-29
Abatement Due Date 2016-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about May 26, 2016, at the above addressed site, employees were exposed to fall hazards of approximately 25 feet 4 inches and 19 feet when performing form removal work from a fabricated frame scaffold prior to the employer providing them with a training program for them to recognize the hazards associated with the scaffold. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.