Search icon

ZE CONSTRUCTION, LLC. - Florida Company Profile

Company Details

Entity Name: ZE CONSTRUCTION, LLC.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ZE CONSTRUCTION, LLC. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 26 May 2015 (10 years ago)
Date of dissolution: 14 Nov 2016 (8 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 14 Nov 2016 (8 years ago)
Document Number: L15000092379
FEI/EIN Number 47-4105294

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 133 JOCELYN DR., DAVENPORT, FL, 33897, US
Mail Address: 133 JOCELYN DR., DAVENPORT, FL, 33897, US
ZIP code: 33897
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
URGILES ZOILA Authorized Member 133 JOCELYN DR., DAVENPORT, FL, 33897
URGILES ZOILA Agent 133 JOCELYN DR., DAVENPORT, FL, 33897

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2016-11-14 - -

Documents

Name Date
ANNUAL REPORT 2016-01-20
Florida Limited Liability 2015-05-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341518256 0420600 2016-06-02 27023 JUNIPER BAY DRIVE, WESLEY CHAPEL, FL, 33544
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-06-02
Emphasis L: FORKLIFT, L: FALL, P: FORKLIFT
Case Closed 2016-07-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2016-06-28
Current Penalty 1056.0
Initial Penalty 1760.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On the roof at the jobsite, eye protection was not provided to employees operating pneumatic nail guns, exposing employees to a struck by hazard on or about 6/2/16.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-06-28
Current Penalty 1848.0
Initial Penalty 3080.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 5/12 pitch roof, fall protection was not provided to employees doing framing work, carrying plywood, and installing plywood sheeting, exposing the employees to a fall hazards between 19 feet 4 inches and 8 feet 8 inches, on or about 6/2/16.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-06-28
Current Penalty 1320.0
Initial Penalty 2200.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. At the jobsite, the portable extension ladder used to access the second story roof area extended approximately 20 inches or 1-1/2 rungs past the upper landing surface, exposing the employees to a 19 foot 4 inch fall hazard, on or about 6/2/16.
341363182 0420600 2016-03-30 2511 NORTH GANDY AVE., TAMPA, FL, 33607
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2016-03-30
Emphasis L: FALL, P: FALL
Case Closed 2016-08-23

Related Activity

Type Inspection
Activity Nr 1136222
Safety Yes
Type Inspection
Activity Nr 1135198
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2016-06-03
Abatement Due Date 2016-06-15
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: At the Grady Square Apts., Section 7, located at 2511 North Grady Avenue,, Tampa, FL 33697. (a) For employees that were working on the roof the HVAC hole was covered with plywood that was not secured to the floor, resulting in an employee from another company to fall 43'-7" through the HVAC hole, on or about 03/21/2016.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2016-06-03
Abatement Due Date 2016-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: At the Grady Square Apts., Section 7, located at 2511 North Grady Avenue,, Tampa, FL 33697. (a) For employees that were working on the roof, the HVAC hole was covered with plywood that was not marked with a warning word, resulting in an employee from another company to fall 43'-7" through the HVAC hole, on or about 03/21/2016.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2016-06-03
Abatement Due Date 2016-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-27
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. At the Grady Square Apts., Section 7, located at 2511 North Grady Avenue,, Tampa, FL 33697. (a) For employees that were trained in fall protection no written (training) certificate record was provided with the signature of the trainer, observed on or about 03/30/2016.