Entity Name: | ORANGE CONSTRUCTION, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
ORANGE CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 19 May 2015 (10 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 15 Dec 2015 (9 years ago) |
Document Number: | L15000088258 |
FEI/EIN Number |
47-4060523
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 310 BRUNSON BLVD, COCOA, FL, 32922, US |
Mail Address: | 2330 PALM LAKE DRIVE, MERRITT ISLAND, FL, 32952, US |
ZIP code: | 32922 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
MARSHALL STEVEN | President | 2330 PALM LAKE DRIVE, MERRITT ISLAND, FL, 32952 |
Marshall James CJr. | Member | 821 Del Rio Way, Merritt Island, FL, 32953 |
MARSHALL STEVEN A | Agent | 2330 PALM LAKE DRIVE, MERRITT ISLAND, FL, 32952 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2021-11-02 | 310 BRUNSON BLVD, STE 108, COCOA, FL 32922 | - |
LC AMENDMENT | 2015-12-15 | - | - |
LC AMENDMENT | 2015-07-30 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-03 |
ANNUAL REPORT | 2024-01-03 |
ANNUAL REPORT | 2023-01-30 |
ANNUAL REPORT | 2022-01-14 |
AMENDED ANNUAL REPORT | 2021-11-02 |
AMENDED ANNUAL REPORT | 2021-10-19 |
ANNUAL REPORT | 2021-01-06 |
AMENDED ANNUAL REPORT | 2020-08-20 |
ANNUAL REPORT | 2020-01-02 |
ANNUAL REPORT | 2019-01-02 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347444853 | 0419730 | 2024-04-29 | 3800 S RIO GRANDE AVE, ORLANDO, FL, 32839 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1744642 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-05-16 |
Current Penalty | 2074.2 |
Initial Penalty | 3457.0 |
Final Order | 2024-06-10 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about April 29, 2024, at Nosidnarg Properties: employees were exposed to 8- foot 6-inch fall hazards while removing shingles and underlayment on a 3/12 pitched roof, in that a fall protection system was not used. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2024-05-16 |
Current Penalty | 2074.2 |
Initial Penalty | 3457.0 |
Final Order | 2024-06-10 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22):Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall. a. On or about April 29, 2024, at Nosidnarg Properties,, employees were exposed to an 8-foot, 6-inch fall hazard, in that, employees were allowed to carry underlayment material on a Werner Aluminum Extension Ladder. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-05-16 |
Abatement Due Date | 2024-06-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-06-10 |
Nr Instances | 1 |
Nr Exposed | 6 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about April 29, 2024, at Nosidnarg Properties: the employer did not prepare and maintain a written fall protection training program certification for employees exposed to fall hazards of 8 feet 6 inches while working on the roof. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State