Entity Name: | WOOD DREAMZ LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
WOOD DREAMZ LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 19 May 2015 (10 years ago) |
Date of dissolution: | 22 Sep 2017 (8 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2017 (8 years ago) |
Document Number: | L15000088229 |
FEI/EIN Number |
NOT APPLICABLE
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 7158 SE SR 100, STARKE, FL, 32091, US |
Mail Address: | 7158 SE SR 100, STARKE, FL, 32091, US |
ZIP code: | 32091 |
County: | Bradford |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
DAUGHERTY JOHN | Authorized Member | 7158 SE SR 100, STARKE, FL, 32091 |
DAUGHERTY JOHN | Agent | 7158 SE SR 100, STARKE, FL, 32091 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2016-04-05 |
Florida Limited Liability | 2015-05-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341324234 | 0419700 | 2016-03-15 | 730 OLD LAWTEY RD, STARKE, FL, 32091 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2016-03-17 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2016-04-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone: a. On March 15, 2016, on the 4:12 pitch roof, two employees installing shingles are not protected from an 11 feet fall hazard by the use of a fall protection system. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 A01 |
Issuance Date | 2016-03-17 |
Abatement Due Date | 2016-04-05 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-04-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards: a. On March 15, 2016, employees working from elevations are not trained about fall protection and procedures to minimize those hazards. |