345438667
|
0419700
|
2021-07-20
|
219 PEPPERPIKE WAY, SAINT AUGUSTINE, FL, 32092
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-07-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-08-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2021-10-22 |
Current Penalty |
1500.0 |
Initial Penalty |
2574.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On the 5:12 pitch roof, at the front of the house, at 219 Pepperpike Way in Saint Augustine, Florida: On or about July 20, 2021, the employer exposed three framing employees to a 10 feet fall hazard at the roof eave in that the roof access ladder rails were not extended 3 feet above the upper landing surface of the roof when they accessed the roof to install sheathing boards. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-10-22 |
Abatement Due Date |
2021-11-18 |
Current Penalty |
6200.0 |
Initial Penalty |
10299.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees performing roof sheathing are not protected from fall hazards by the use of a fall protection system. Father N Sons Construction, LLC fails to assure effective protections against falls as required by the standard, as demonstrated on the 5:12 pitch roof, on all slopes of the roof, at 219 Pepperpike Way in Saint Augustine, Florida: On or about July 20, 2021, the employer exposed three framing employees to a 10 feet fall hazard from the roof eaves and a fall hazard of up to 18 feet through the trusses while installing roof sheathing boards in that they were not protected by a fall protection system. Father N Son Construction, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1301214, Serious citation number 1, item number 1 and was affirmed as a final order on September 14, 2021, with respect to a workplace located at 119 Palisade Drive, Saint Augustine, Florida. |
|
|
343012142
|
0419700
|
2018-03-13
|
119 PALISADE DRIVE (LOT 112) SHEARWATER SUBDIVISION, SAINT AUGUSTINE, FL, 32092
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-03-13
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-08-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1308785 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1303103 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-03-21 |
Abatement Due Date |
2018-11-14 |
Current Penalty |
8000.0 |
Initial Penalty |
16629.0 |
Contest Date |
2018-04-13 |
Final Order |
2018-09-14 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about March 13, 2018, on the rooftop, an employee performing sheathing work from a 6:12 pitch roof was not protected from 9 feet 2 inches fall hazards by the use of a fall protection system. b. On or about March 13, 2018, on the rooftop, employees installing roof underlayment from a 6:12 and 3:12 pitch roofs were not protected from 9 feet 2 inches fall hazards by the use of a fall protection system. Father N Son Construction, LLC was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard, 1926.501(b)(13), which was contained in OSHA inspection number 1220052, citation number 2, item number 1 and was affirmed as final order on June 15, 2017, with respect to a workplace located at 625 Stone Ridge Drive Lot 138, Ponte Vedra, Florida. Father N Son Construction, LLC was previously cited for a serious violation of this occupational safety and health standard or its equivalent standard, 1926.501(b)(13), which was contained in OSHA inspection number 1097166, citation number 1, item number 1 and was affirmed as final order on December 16, 2015, with respect to a workplace located at 341 Trellis Bay Rd., Saint Augustine, Florida. |
|
|