Search icon

GULF 2 BAY ROOFING, LLC - Florida Company Profile

Company Details

Entity Name: GULF 2 BAY ROOFING, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

GULF 2 BAY ROOFING, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 23 Dec 2014 (10 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: L14000194753
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7922 LEO KIDD AVE, PORT RICHEY, FL, 34668, US
Mail Address: 7922 LEO KIDD AVE, PORT RICHEY, FL, 34668, US
ZIP code: 34668
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FURMAN FRANCIS HIII Manager 7922 LEO KIDD AVE, PORT RICHEY, FL, 34668
FURMAN FRANCIS HIII Agent 7922 LEO KIDD AVE, PORT RICHEY, FL, 34668

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -

Documents

Name Date
ANNUAL REPORT 2015-04-27
Florida Limited Liability 2014-12-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341006021 0420600 2015-10-20 1645 FIREWHEEL DR, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-10-20
Emphasis P: FALL, L: FALL, L: EISAOF
Case Closed 2019-12-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-10-29
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-11-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. During residential roofing work, employees were exposed to eye injuries, in that, safety glasses were not provided while using air operated nail-guns, on or about 10/20/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-10-29
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-11-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 29 CFR 1926.501(b): a. During residential roofing work, employees were exposed to a fall hazard up to 16 feet high, in that, three employees were stripping and installing roofing shingles without any type of fall protection, on or about 10/20/2015.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-10-29
Abatement Due Date 2015-11-10
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-11-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. During residential roofing work, employees exposed to a fall hazard were not provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitations of fall protection equipment and fall protection systems, on or about 10/20/2015.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-10-29
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-11-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. During residential roofing work, employees were exposed to a 12 feet fall hazard, in that, an extension ladder used to gain access to the roof extended 1 foot 6 inches from the landing surface, on or about 10/20/2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2015-10-29
Abatement Due Date 2015-12-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-11-18
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities, on or about 10/20/2015.

Date of last update: 01 Apr 2025

Sources: Florida Department of State