Search icon

PONCE E CONSTRUCTION SERVICE LLC

Company Details

Entity Name: PONCE E CONSTRUCTION SERVICE LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Inactive
Date Filed: 10 Dec 2014 (10 years ago)
Date of dissolution: 18 Jul 2019 (6 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 18 Jul 2019 (6 years ago)
Document Number: L14000188487
FEI/EIN Number 47-2523407
Address: 15250 Keylime Blvd, Loxahatchee, FL 33470
Mail Address: 15250 Keylime Blvd, Loxahatchee, FL 33470
ZIP code: 33470
County: Palm Beach
Place of Formation: FLORIDA

Agent

Name Role Address
PONCE, ENGRACIO Agent 15250 Keylime Blvd, Loxahatchee, FL 33470

Manager

Name Role Address
PONCE, ENGRACIO Manager 15250 Keylime Blvd, Loxahatchee, FL 33470

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2019-07-18 No data No data
CHANGE OF PRINCIPAL ADDRESS 2017-03-03 15250 Keylime Blvd, Loxahatchee, FL 33470 No data
CHANGE OF MAILING ADDRESS 2017-03-03 15250 Keylime Blvd, Loxahatchee, FL 33470 No data
REGISTERED AGENT ADDRESS CHANGED 2017-03-03 15250 Keylime Blvd, Loxahatchee, FL 33470 No data

Documents

Name Date
VOLUNTARY DISSOLUTION 2019-07-18
ANNUAL REPORT 2019-03-11
ANNUAL REPORT 2018-03-10
ANNUAL REPORT 2017-03-03
ANNUAL REPORT 2016-04-28
ANNUAL REPORT 2015-05-12
Florida Limited Liability 2014-12-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342428497 0418800 2017-06-27 421 MARS WAY, JUNO BEACH, FL, 33408
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-06-27
Emphasis L: FALL, P: FALL
Case Closed 2018-04-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 1088.0
Initial Penalty 2173.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall of approximately 7 feet 2 inches when performing steel reinforcement bar installation from the work level platform of a fabricated frame scaffold that was not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about June 27, 2017, at the above addressed site, an employee was exposed to fall hazard of approximately 7 feet 2 inches when performing steel reinforcement bar installation work from a fabricated frame scaffold that was not erected by a competent person in scaffold erection.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall hazard of approximately 7 feet 2 inches when performing steel reinforcement bar installation work from a fabricated frame scaffold prior to being provided with training for the hazards associated with scaffolds.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 1088.0
Initial Penalty 2173.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall hazard of approximately 7 feet 2 inches when performing steel reinforcement bar installation work from a fabricated frame scaffold that did not have the scaffold frame legs bearing on baseplates and/or mudsills.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall hazard of approximately 7 feet 2 inches when performing steel reinforcement bar installation work from a fabricated frame scaffold which had the frame legs supported on unstable concrete blocks.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 1088.0
Initial Penalty 2173.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall of approximately 12 feet 8 inches when installing steel reinforcement bars on a walking/working surface of a residence under construction while not being protected from falling to the lower level.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2017-07-26
Abatement Due Date 2017-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about June 27, 2017, at the above addressed site, an employee was exposed to a fall hazard of approximately 12 feet 8 inches when performing steel reinforcement bar installation work from walking/working surface of a residence prior to being provided with training for the hazards associated with scaffolds.