Entity Name: | HIGH TECH COMPOSITES II, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
HIGH TECH COMPOSITES II, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 28 Aug 2014 (11 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 24 Sep 2015 (10 years ago) |
Document Number: | L14000135394 |
FEI/EIN Number |
47-1715293
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2910 DUSA DRIVE, MELBOURNE, FL, 32934, US |
Mail Address: | 2910 DUSA DRIVE, MELBOURNE, FL, 32934, US |
ZIP code: | 32934 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SUSAN L TAYLOR, LLC | Agent | - |
WRIGHT DOUG S | Managing Member | 2910 DUSA DRIVE, MELBOURNE, FL, 32934 |
WRIGHT DOUGLAS SSR. | Managing Member | 2910 DUSA DRIVE, MELBOURNE, FL, 32934 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2023-04-27 | SUSAN L TAYLOR, LLC | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-04-27 | 217 woodside drive, tallahassee, fl, FL 32304 | - |
LC AMENDMENT | 2015-09-24 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-10 |
ANNUAL REPORT | 2023-04-27 |
ANNUAL REPORT | 2022-04-28 |
ANNUAL REPORT | 2021-04-30 |
ANNUAL REPORT | 2020-03-24 |
ANNUAL REPORT | 2019-04-29 |
ANNUAL REPORT | 2018-04-30 |
ANNUAL REPORT | 2017-01-12 |
ANNUAL REPORT | 2016-04-11 |
LC Amendment | 2015-09-24 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344964200 | 0420600 | 2020-10-08 | 2910 DUSA DRIVE, MELBOURNE, FL, 32934 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1666911 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100134 C |
Issuance Date | 2020-12-31 |
Abatement Due Date | 2021-01-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-01-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) High Tech Composites II - A written respiratory protection program was not developed and employees were required to wear 3M half-face respirators, on or about October 21, 2020. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100134 F01 |
Issuance Date | 2020-12-31 |
Abatement Due Date | 2021-01-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-01-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: a) High Tech Composites II - Fit tests were not conducted and employees were required to wear 3M half-face respirators, on or about October 21, 2020. |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19100134 G01 I A |
Issuance Date | 2020-12-31 |
Abatement Due Date | 2021-01-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-01-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) High Tech Composites II - An employee, wearing a 3M half-face respirator, had a beard, on or about October 21, 2020. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2020-09-22 |
Emphasis | L: FORKLIFT |
Case Closed | 2021-03-29 |
Related Activity
Type | Complaint |
Activity Nr | 1660469 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100178 A04 |
Issuance Date | 2020-12-31 |
Abatement Due Date | 2021-01-28 |
Current Penalty | 2313.0 |
Initial Penalty | 2313.0 |
Final Order | 2021-01-28 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals were not changed accordingly: (a) At the workplace: On or about September 22, 2020, fork extensions were used without written approval from the manufacturer or a qualified registered professional engineer, exposing employees to a struck-by hazard. (b) At the workplace: On or about September 22, 2020, a hitch ball was used through a hole in the left fork without written approval from the manufacturer or a qualified registered professional engineer, exposing employees to a struck-by hazard. (c) At the workplace: On or about September 22, 2020, the plates on the forklift were not changed to reflect the use of the fork extensions and hitch ball. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100178 L02 II |
Issuance Date | 2020-12-31 |
Abatement Due Date | 2021-01-28 |
Current Penalty | 2313.0 |
Initial Penalty | 2313.0 |
Final Order | 2021-01-28 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. (a) At the workplace: On or about September 22, 2020, forklift operator training was inadequate, in that, it did not include practical training and an evaluation of the operator's performance. |