Entity Name: | GARNER WALL L.L.C. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
GARNER WALL L.L.C. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 21 Aug 2014 (11 years ago) |
Date of dissolution: | 25 Sep 2015 (10 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 25 Sep 2015 (10 years ago) |
Document Number: | L14000131556 |
Address: | 822 ASHFORD ST., JACKSONVILLE, FL, 32208, US |
Mail Address: | 822 ASHFORD ST., JACKSONVILLE, FL, 32208, US |
ZIP code: | 32208 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
GARNER RAYMOND M | Owner | 822 ASHFORD ST., JACKSONVILLE, FL, 32208 |
GARNER RAYMOND M | Agent | 822 ASHFORD ST., JACKSONVILLE, FL, 32208 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2015-09-25 | - | - |
Name | Date |
---|---|
Florida Limited Liability | 2014-08-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340083260 | 0419700 | 2014-11-06 | 122 OCEAN STREET, JACKSONVILLE, FL, 32208 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1006375 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1008053 |
Safety | Yes |
Type | Referral |
Activity Nr | 918814 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1008354 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 I |
Issuance Date | 2014-12-22 |
Current Penalty | 2400.0 |
Initial Penalty | 2400.0 |
Final Order | 2015-01-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a. On or about November 4, 2014, on the third floor of the commercial building, the tubular framed scaffold system was missing planks on the seventh level where employees were accessing and egressing the scaffolding system while conducting stucco work, exposing themselves to a 9 feet 11-inch feet fall hazard. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2014-12-22 |
Current Penalty | 1700.0 |
Initial Penalty | 1700.0 |
Final Order | 2015-01-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about November 4, 2014, on the third floor of the commercial building, the 7th level of the tubular framed scaffold did not have guardrails at the egress and access point, exposing employees to a 9 feet 11-inch fall hazard. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2014-12-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-01-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. On or about November 4, 2014, the employer did not train employees about working from scaffold systems and the hazards associated with them. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 H02 II |
Issuance Date | 2014-12-22 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-01-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a. On or about November 4, 2014, on the third floor of the building, the tubular framed scaffold did not have toe boards to protect employees from falling debris, material or equipment. |