Entity Name: | UDD CONSTRUCTION LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
UDD CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 11 Aug 2014 (11 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 29 Apr 2022 (3 years ago) |
Document Number: | L14000125429 |
FEI/EIN Number |
47-1555694
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 13750 W COLONIAL DR, WINTER GARDEN, FL, 34787, US |
Mail Address: | 13750 W COLONIAL DR, WINTER GARDEN, FL, 34787, US |
ZIP code: | 34787 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ROJAS DAVID Sr. | Auth | 711 BURCH AVE, WINTER GARDEN, FL, 34787 |
CALDERON CARLA | Treasurer | 13750 W COLONIAL DR, WINTER GARDEN, FL, 34787 |
ROJAS DAVID Sr. | Agent | 13750 W COLONIAL DR, WINTER GARDEN, FL, 34787 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2023-04-24 | ROJAS, DAVID, Sr. | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-04-24 | 13750 W COLONIAL DR, STE 350, WINTER GARDEN, FL 34787 | - |
REINSTATEMENT | 2022-04-29 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2020-09-25 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2017-03-31 | 13750 W COLONIAL DR, STE 350, WINTER GARDEN, FL 34787 | - |
CHANGE OF MAILING ADDRESS | 2017-03-31 | 13750 W COLONIAL DR, STE 350, WINTER GARDEN, FL 34787 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-05 |
ANNUAL REPORT | 2024-04-25 |
ANNUAL REPORT | 2023-04-24 |
REINSTATEMENT | 2022-04-29 |
ANNUAL REPORT | 2019-02-28 |
ANNUAL REPORT | 2018-04-26 |
ANNUAL REPORT | 2017-03-31 |
ANNUAL REPORT | 2016-03-29 |
AMENDED ANNUAL REPORT | 2015-10-23 |
ANNUAL REPORT | 2015-01-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343524831 | 0420600 | 2018-10-05 | 2932 BUSHMEAD CT., OCOEE, FL, 34761 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B01 |
Issuance Date | 2019-03-29 |
Abatement Due Date | 2019-05-15 |
Current Penalty | 1023.0 |
Initial Penalty | 1705.0 |
Final Order | 2019-04-11 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) at the worksite - the employer did not initiate and maintain an accident prevention program, also known as a safety and health program, on or about 10/5/18. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-03-29 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-04-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) roof - 2 employees were exposed to a fall of 17 feet 5 inches while doing roof sheathing, on or about 10/5/18. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2019-03-29 |
Abatement Due Date | 2019-05-15 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-04-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) roof - 2 employees were exposed to a fall of 17 feet 5 inches while roof sheathing and the employees were not trained, on or about 10/5/18. |