Search icon

BREVARD FRAMING AND DRYWALL, LLC - Florida Company Profile

Company Details

Entity Name: BREVARD FRAMING AND DRYWALL, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

BREVARD FRAMING AND DRYWALL, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 17 Jul 2014 (11 years ago)
Document Number: L14000113492
FEI/EIN Number 47-1377689

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 709 SILVER PALM AVENUE, SUITE D, MELBOURNE, FL, 32901
Mail Address: 709 SILVER PALM AVENUE, SUITE D, MELBOURNE, FL, 32901
ZIP code: 32901
County: Brevard
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BONENBERGER JAMES R Manager 709 SILVER PALM AVENUE, SUITE D, MELBOURNE, FL, 32901
FRESE GARY B Agent 2200 FRONT STREET, SUITE 301, MELBOURNE, FL, 32901

Documents

Name Date
ANNUAL REPORT 2025-01-29
ANNUAL REPORT 2024-02-02
ANNUAL REPORT 2023-01-26
ANNUAL REPORT 2022-02-01
ANNUAL REPORT 2021-02-01
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-01-31
ANNUAL REPORT 2018-04-03
ANNUAL REPORT 2017-08-15
ANNUAL REPORT 2016-03-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344470109 0420600 2019-11-23 2404 METFIELD DR., MELBOURNE, FL, 32940
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-11-23
Emphasis L: FALL
Case Closed 2020-06-16

Related Activity

Type Referral
Activity Nr 1521021
Safety Yes
Type Inspection
Activity Nr 1447030
Safety Yes
Type Inspection
Activity Nr 1447025
Safety Yes
Type Inspection
Activity Nr 1472292
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260251 A01
Issuance Date 2020-05-08
Current Penalty 5667.6
Initial Penalty 9446.0
Final Order 2020-06-09
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe: a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities were exposed to a struck by hazard, in that, four landscape timbers used as rigging to lift a 10,000 pound roof section were not inspected.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261425 B
Issuance Date 2020-05-08
Current Penalty 5667.6
Initial Penalty 9446.0
Final Order 2020-06-09
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(b): While the operator was not moving the suspended load, no employee shall be within the fall zone, except those employees engaged in; (b)(1): hooking, unhooking or guiding a load; (b)(2) initial attachment of the load to a component or structure or (b)(3) operating a concrete hopper or bucket. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, the employees were working directly beneath a suspended 10,000 pound, 32' 3" by 32' 3" roof section attaching braces.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261425 C01
Issuance Date 2020-05-08
Current Penalty 5667.6
Initial Penalty 9446.0
Final Order 2020-06-09
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(1): The employer did not make sure that the materials being hoisted when employees were hooking, unhooking, or guiding the load were rigged to prevent unintentional displacement. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, four landscape timbers were used as rigging to lift a 10,000 pound roof section. Landscape timbers were run along the top chord of cold steel formed metal trusses with no rigging securely holding the roof section in place.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261425 C03
Issuance Date 2020-05-08
Current Penalty 5667.6
Initial Penalty 9446.0
Final Order 2020-06-09
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(3): The materials were not rigged by a qualified rigger. a) Home 2 Suites, Viera Town Center, 2404 Metfield Dr. - observed on or about November 23, 2019, employees in the process of framing activities we exposed to a struck by hazard, in that, the load was not rigged by a qualified rigger.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1428148308 2021-01-17 0455 PPS 709 Silver Palm Ave, Melbourne, FL, 32901-4803
Loan Status Date 2021-11-11
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 231186.38
Loan Approval Amount (current) 231186.38
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17616
Servicing Lender Name Seacoast National Bank
Servicing Lender Address 815 Colorado Ave, STUART, FL, 34994-3053
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Melbourne, BREVARD, FL, 32901-4803
Project Congressional District FL-08
Number of Employees 19
NAICS code 238130
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 124402
Originating Lender Name Seacoast National Bank
Originating Lender Address Melbourne, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 232856.06
Forgiveness Paid Date 2021-10-08
1084827103 2020-04-09 0455 PPP 701 Silver Palm Ave, Melbourne, FL, 32901-4633
Loan Status Date 2021-02-17
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 231186
Loan Approval Amount (current) 231186
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17616
Servicing Lender Name Seacoast National Bank
Servicing Lender Address 815 Colorado Ave, STUART, FL, 34994-3053
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Melbourne, BREVARD, FL, 32901-4633
Project Congressional District FL-08
Number of Employees 16
NAICS code 238130
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 124402
Originating Lender Name Seacoast National Bank
Originating Lender Address Melbourne, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 232900.63
Forgiveness Paid Date 2021-01-07

Date of last update: 01 Mar 2025

Sources: Florida Department of State